39
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC 2366672
Problem
Cause
Remedy
Pump runs fast when the
spray gun is closed.
Valves worn.
Replace the parts.
Loss of power due to severe
icing.
There is a lot of condensation
water in the air supply.
Install a water separator.
If none of the causes of malfunction mentioned are present, the defect can be remedied by a WAGNER Service
Center.
10
REPAIR WORK
10.1
REPAIR STAFF
Repair work should be undertaken carefully by qualifi ed and trained personnel. They
should be informed of specifi c hazards during their training.
The following hazards may arise during repair work:
- Health hazard from inhaling solvent vapors
- Use of unsuitable tools and aids
A skilled person must check to ensure that the device is in a reliable state after it is repaired.
Carry out function test in accordance with Chapter 11.
10.2
SAFETY INSTRUCTIONS
Observe the safety instructions in Chapter 4 and Chapter 8.1.2.
Before a Repair
- Flush and clean the system. Chapter 8.1.3.
After a Repair
- Carry out a safety checks in accordance with Chapter 8.2.3.
- Put the system into operation and check for leaks as described in Chapter 6.7.
- Function test in accordance with Chapter 11.
According DGUV regulation 100-500:
- The liquid ejection devices should be checked by an expert (e.g., WAGNER service
technician) for their safe working conditions as required and at least every
12 months.
- For shut down devices, the examination can be suspended until the next start-up.