26
B_05377
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC 2366672
Procedure:
1. Screw on grounding cable with eye.
2. Clamp the grounding cable clip to a
grounding connection on site.
3. Ground the product (paint) tank to an on-
site grounding connection.
4. Ground the other parts of the system to an
on-site grounding connection.
Carry out safety checks in accordance with Chapter 8.2.3.
6.7
SAFETY CHECKS
Before every start-up, the following points should be observed:
-
Secure gun with safety clip.
-
Check the permissible pressures.
-
Check all connections for leaks.
-
Check hoses for damage.
It should be ensured that the device is in the following state before carrying out any
work on it:
-
The pressure should be released from the pump and high-pressure hose with gun.
-
The gun should be secured with the safety clip.
-
The air supply should be interrupted.
Pressure tightness test
For pressure tightness control of the entire installation, the fl ushing agent product pressure is slowly
increased step by step until the product pressure of the pump indicated on the type plate is reached.
Overpressure!
Risk of injury from bursting components.
The operating pressure must not exceed the value shown on
the type plate.
WARNING