background image

 

2021 

Preliminary Installation Procedures for 
WAGENER SPARKY RU – Rural Woodburner 

 

To get the full benefit from the Wagener Sparky RU Woodburner it is important that it is installed correctly, 
both for efficiency and safety sake. The following points should be noted:- 

 

1.

 

The characteristics of the Wagener Sparky RU will determine its position within the home.  
As a general rule an interior wall installation suits flue requirements better than against an exterior 
wall.  

2.

 

Check for flue obstructions above the ceiling. (header tanks, electrical mains or load bearing roof 
supports and the like). 

3.

 

The recommended vertical flue height for optimum operation is 4.2metres above the top of Sparky 
RU’s Flue Collar Panel. The performance of Sparky RU depends more on the flue than on any other 
single component. It is the draw on the flue that drives the stove. 

4.

 

Remember a permit is required from your Local Authority. 

 

Flue System  

 

Must be manufactured in accordance with AS/NZS 2918-2001 and tested to Appendix F.  

See installation instructions on pages 4, 5 & 6.  
PLEASE NOTE

A purpose designed and tested petite flue system is available for Sparky RU 

using a 100/150/200mm system with a reduced flue shield and ceiling plate. 

 

Flue Shield 

 

Sparky RU requires a single flue shield standing 1000mm high and spaced 30mm above the flue collar panel. 
Please refer to fitting instructions supplied with the flue shield. 

 

Floor Protector/Hearth Requirements & Positioning 

 

Sparky RU

 requires an 

ash hearth floor protector only 

of a minimum size of 610mm wide and 865mm 

deep. (eg Tiles, slate, treadle plate etc)  
The Ash Hearth floor protector shall have an upper surface, including grouting if required, of a durable,  
non-combustible material.  
All joints in the surface must be sealed to protect and prevent ash or spilled embers reaching the floor. 

 

Floor protection must extend under Sparky RU and forward 300mm and be 200mm from each side of the 
firebox door opening. (120mm from the side panel to each side) 
For concrete floors trim back any floor coverings to no less than the minimum hearth requirement. 

 

NOTE: SPARKY RU MUST BE AFFIXED TO THE HEARTH AND FLOOR FOR SEISMIC RESTRAINT. 

 

For Seismic Restraint secure through two holes at the rear of the log box base and screw through the hearth 
and into the floor. 

 

Wet Back Fitting  

 

Sparky RU

 can be fitted with a wet back. We recommend that you use the “Lion” Wet Back which has been 

designed and tested specifically for Sparky RU. In general, wet backs are factory fitted at the time of ordering. 
However, a suitably qualified person can fit or change the wet back out in the field if this is required. Water 
MUST always be present in the wet back. The wet back MUST be connected by a Registered Plumber to an 
open vented system. Tempering valves are required. Please check the PH level of the water supply as wet 
backs can become fouled with lime which will void the warranty. NB Some coals are very corrosive and may 
shorten the life of the wet back – please check with the supplier as this is NOT covered by warranty. Please 
advise the householders NOT to boil the wet back as this will cause vibrations and will fatigue the wet back, 
the pipes and the cylinder. This will NOT be covered by the warranty. 

 

Содержание Sparky RU

Страница 1: ...staller s Responsibilities The Wagener Sparky RU must be installed in accordance with these installation instructions to comply with AS NZS 2918 2001 Domestic Solid Fuel burning appliances Any variati...

Страница 2: ...minimum size of 610mm wide and 865mm deep eg Tiles slate treadle plate etc The Ash Hearth floor protector shall have an upper surface including grouting if required of a durable non combustible mater...

Страница 3: ...001 Please ask your retailer or contactWagener Stoves if you need further advice Installation Clearances AS NZ Standard 2918 2001 WAGENER 100 370 370 797 797 865 485 460 540 340 797 865 160 Ashlip to...

Страница 4: ...E PIPE 150MM INNER CASING CEILING PLATE CERAMIC CEILING SPACER NOGGING Ash Hearth Floor Protector 100mm Flue Pipe Flue Flange Flue Shield Flue collar panel WAGENER Sparky RU 4 2 Metres from above flue...

Страница 5: ...proposed position and mark a point on the ceiling that is directly above the centre of the Woodburners Flue Spigot Check that the Woodburners location allows the OUTER CASING to clear all the structu...

Страница 6: ...e bottom FLUE PIPE securing the 3 Monel rivets 10 Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and then from the roof slide the INNER CASING into the OUTE...

Страница 7: ...BREACHING AS NZS2918 2001 6 WARNING OPEN AIR CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE...

Страница 8: ...of the firebox Stack kindling around the newspaper like an Indian Tepee and light the newspaper or firelighters if using leaving the door slightly ajar until the kindling is well alight Then add 2 or...

Страница 9: ...causing damage Fire Box Bricks Fire Bricks serve two purposes Firstly to protect the steel chassis and secondly to maintain high temperatures in the fire box to effect complete combustion of the fuel...

Отзывы: