100mm / 200mm Free Standing Woodburner Flue Kit 
Installation Instructions 

(continued)

 

 
 

 
Note

 that the INNER CASING MUST extend 200mm above roof penetration.  

 

NB

: Do not secure the OUTER CASING SLIP EXTENSION onto the OUTER CASING, as a final adjustment 

will be required when fitting cowl assembly. See paragraph 11.  
 
5. Fix an appropriate flashing around the OUTER CASING to seal onto the roofing material. Refer to the 
manufacturer’s recommendations for correct fitting. 

NB

: On iron roofs, fixings such as metal angle brackets 

(approximately 25mm x 25mm) can be fitted under the flashing to securely fix the roof to OUTER CASING.  
 
6. Place CEILING PLATE over Woodburners Flue Spigot, ensuring the folded edges are facing the ceiling.   
 
7. Position bottom length of FLUE PIPE (crimped end downwards) into Woodburner Flue Spigot.  
    Ensure the connection is well sealed using a suitable flue pipe sealant such as maniseal fire cement. 
 
8. Assemble FLUE PIPES together ensuring seams are straight, offsetting the seams will ensure a neat fit. FLUE 
PIPES 

must 

be assembled with crimped ends down (towards Woodburner). Secure each joint with a 

minimum of three Monel Steel Rivets equally spaced around the joint. If using HI-THERM FLUE PIPE the 
protective wrapping should be left on the FLUE PIPE during installation.   
 
9. From the roof lower FLUE PIPE through OUTER CASING into the bottom FLUE PIPE securing the 3 
Monel rivets.    
 
10. Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and 
then from the roof slide the INNER CASING into the OUTER CASING until the brackets rest on to the 
internal swage ring of the OUTER CASING, this will ensure the INNER CASING is the correct 12mm above 
ceiling level.  
Check the INNER CASING when correctly positioned extends a minimum of 200mm above the roof 
penetration.   
 
11. Before securing the OUTER CASING SLIP EXTENSION to the OUTER CASING with 3 rivets, ensure the 
FLUE PIPE is either flush or extends above the top of the OUTER CASING SLIP EXTENSION by no more 
than 15mm. Adjust SLIP EXTENSION to obtain this measurement.  
 
12. Push CASING COVER (with spigot inside FLUE PIPE) down onto the OUTER CASING SLIP 
EXTENSION. The 3 locating brackets with holes must be on the outside of the OUTER CASING SLIP 
EXTENSION and are secured using 3 rivets.   
 
13. Fit COWL but do not secure, as removal for flue cleaning will be necessary. Deform or ovalise the stub of 
the COWL to ensure it is a tight friction fit.   
 
14. Fasten CELING PLATE to ceiling using screws and ceramic spacers required. Ensure an even air gap 
around FLUE PIPE when fixing. Remove protective plastic from CEILING PLATE 

N.B

 12mm air gap between 

ceiling plate and ceiling must be maintained.  
 
 15. Using brackets provided fit the flue shield to the rear of the flue pipe with a 30mm gap between the stove 
top collar and lower edge of shield. (See diagram page 4) 
 
 16. Please leave all instructions with the owner.   

Содержание Sparky RU

Страница 1: ...staller s Responsibilities The Wagener Sparky RU must be installed in accordance with these installation instructions to comply with AS NZS 2918 2001 Domestic Solid Fuel burning appliances Any variati...

Страница 2: ...minimum size of 610mm wide and 865mm deep eg Tiles slate treadle plate etc The Ash Hearth floor protector shall have an upper surface including grouting if required of a durable non combustible mater...

Страница 3: ...001 Please ask your retailer or contactWagener Stoves if you need further advice Installation Clearances AS NZ Standard 2918 2001 WAGENER 100 370 370 797 797 865 485 460 540 340 797 865 160 Ashlip to...

Страница 4: ...E PIPE 150MM INNER CASING CEILING PLATE CERAMIC CEILING SPACER NOGGING Ash Hearth Floor Protector 100mm Flue Pipe Flue Flange Flue Shield Flue collar panel WAGENER Sparky RU 4 2 Metres from above flue...

Страница 5: ...proposed position and mark a point on the ceiling that is directly above the centre of the Woodburners Flue Spigot Check that the Woodburners location allows the OUTER CASING to clear all the structu...

Страница 6: ...e bottom FLUE PIPE securing the 3 Monel rivets 10 Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and then from the roof slide the INNER CASING into the OUTE...

Страница 7: ...BREACHING AS NZS2918 2001 6 WARNING OPEN AIR CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE...

Страница 8: ...of the firebox Stack kindling around the newspaper like an Indian Tepee and light the newspaper or firelighters if using leaving the door slightly ajar until the kindling is well alight Then add 2 or...

Страница 9: ...causing damage Fire Box Bricks Fire Bricks serve two purposes Firstly to protect the steel chassis and secondly to maintain high temperatures in the fire box to effect complete combustion of the fuel...