EN
Technical data
AirCon Service Center
138
AirCon Service Center
ASC 3300 G
Dimensions (width x height x depth):
560 mm x 1300 mm x 650 mm
Weight:
105 kg
Power supply:
230 V/240 V – 50 Hz/60 Hz
Refrigerant extraction rate:
18 kg/h
Vacuum pump output:
192 l/h
Hermetic compressor output:
0.32 kW
Drier filter output:
150 kg
Vacuum pump oil service life:
60 h
Filling cylinder accumulator capacity:
30.0 l/28.0 kg
Noise emission*:
62 dB (A)
Accuracy of the electronic scale for refrigerant:
± 10 g
Accuracy of the electronic scale for old/new oil:
± 1 g
Accuracy of the electronic scale for UV additive:
± 1 g
Maximum permissible pressure:
-1 bar to +20 bar
Refrigerant:
R-134a
Oil:
any refrigerating unit oil used in
the motor vehicle sector
Maximum permissible operating temperature:
+5 °C to +40 °C
Storage temperature range:
–25 °C to +50 °C
*
In accordance with DIN EN ISO 3746, the workplace-related emission value LpA of an
air-conditioning service station was determined in various operating conditions. Both the
average dB(A) values and the maximum dB(C) peak values are well below the maxi-
mum permissible exposure values.
Measurements: 62 dB(A), 74 dB(C)
ASC1300G-ASC2300G-ASC3300G_OPM_DE-EN-ES-FR-RU.book Seite 138 Dienstag, 30. Juni 2020 2:12 14