EN
127
AirCon Service Center
Service tasks
9.8
Correcting the filling quantity for long service
hoses
I
1. In the basic menu, use the cursor keys
or
to select
“Other
selections”
:
2. Press
ENTER
to confirm.
3. Use the cursor keys
or
to select
“Service”
:
4. Press
ENTER
to confirm.
5. Enter the password
“7732”
.
6. Enter the hose length in centimetres.
7. Press
ENTER
to confirm.
9.9
Replacing the printer paper
1. To replace the printer paper roll (
14
), open the cover (
K
).
2. Insert the new paper roll and close the cover (
K
).
NOTE
If longer or shorter service hoses are required for the device, you
need to adjust the filling quantities to the new hose lengths.
The service hoses for the high and low pressure sides must always
be of the same length, as otherwise the filling quantities will not be
correctly measured.
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.
K
ASC1300G-ASC2300G-ASC3300G_OPM_DE-EN-ES-FR-RU.book Seite 127 Dienstag, 30. Juni 2020 2:12 14