EN
Technical data
AirCon Service Center
136
13
Technical data
The display shows
“Error 60”
During the hybrid service
(flushing the service hoses
with hybrid oil), a vacuum
could not be achieved.
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Check the connections for
leaks.
The display shows
“Error 61”
Pressure increase during the
hybrid service .
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Are the service couplings
open?
AirCon Service Center
ASC 1300 G
Dimensions (width x height x depth):
560 mm x 1300 mm x 650 mm
Weight:
95 kg
Power supply:
230 V/240 V – 50 Hz/60 Hz
Refrigerant extraction rate:
18 kg/h
Vacuum pump output:
4 cars/h
Hermetic compressor output:
0.2 kW
Drier filter output:
150 kg
Vacuum pump oil service life:
60 h
Filling cylinder accumulator capacity:
12.0 l/10.0 kg
Noise emission*:
62 dB (A)
Accuracy of the electronic scale for refrigerant:
± 10 g
Accuracy of the electronic scale for old/new oil/
UV additive:
± 1 g
Maximum permissible pressure:
-1 bar to +20 bar
Refrigerant:
R-134a
Oil:
any refrigerating unit oil used in
the motor vehicle sector
Maximum permissible operating temperature:
+5 °C to +40 °C
Storage temperature range:
–25 °C to +50 °C
Problem
Cause
Remedy
ASC1300G-ASC2300G-ASC3300G_OPM_DE-EN-ES-FR-RU.book Seite 136 Dienstag, 30. Juni 2020 2:12 14