1
Contact your authorized Wacker Neuson dealer/service center.
10.1
Checking Hydraulic Pressure
There are two test ports for checking the hydraulic pressure (see topic
Hydraulic
Manifold
):
■
Exciter test port (G-EP)
■
Drive test port (G-DP)
No steering
Faulty left/right joystick switch or poor
connection inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on steering valve
Repair or replace.
Loose, broken or corroded wire
connections inside control panel or
transmitter
Repair or replace.
Damaged steering cylinder
Repair or replace.
Locking bar engaged
Disengage locking bar.
Machine out of infra-red signal range
Move transmitter closer to machine.
Operator too close to machine
Move away from machine.
Communication fault
See topic
Communication Faults.
Compatec
compaction
system LEDs
permanently
flashing (if
equipped)
Sensor failure
Repair or replace.
1
Problem
Reason
Remedy
High vibration pressure
Low vibration pressure
2,500 ± 100 psi (172 ± 7 bar)
1,200 ± 100 psi (83 ± 7 bar)
Joystick full forward position
3,000 ± 100 psi (207 ± 7 bar)
Содержание RT82-SC3
Страница 4: ...CALIFORNIA Proposition 65 Warning wc_tx004643en fm 4 Notes...
Страница 8: ...Foreword RT RTx 8 wc_tx003861gb_FM10 fm...
Страница 10: ......
Страница 12: ......
Страница 25: ...wc_si000902gb_FM10 fm 25 RT RTx Safety Information Notes...
Страница 40: ...wc_tx003862gb_FM10 fm 40 Lifting and Transporting RT RTx Notes...
Страница 56: ...wc_tx003863gb_FM10 fm 56 Operation RT RTx wc_gr012189 a b c d e f...
Страница 122: ...wc_td000626gb_FM10 fm 122 Technical Data RT RTx Notes...
Страница 151: ...RT RTx Schematics wc_tx003865gb_FM10 fm 151 14 Schematics Notes...
Страница 178: ......
Страница 180: ......