5.9
Cleaning the Sediment Cup
See Graphic: wc_gr000029
5.9.1
Turn the fuel valve off.
5.9.2
Remove the sediment cup
(a)
and the O-ring
(b)
.
5.9.3
Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
5.9.4
Turn the fuel valve on and check for leaks.