Troubleshooting
PG 2A/3A
36
wc_tx001575gb.fm
6
Troubleshooting
Problem / Symptom
Reason / Remedy
Pump does not take in water.
• Not enough priming water in housing.
• Engine speed too low. Adjust speed.
• Strainer plugged. Clean strainer.
• Suction hose damaged. Replace or repair hose.
• Air leak at suction port. Check that fittings are tight
and sealing properly.
• Pump too high above water.
• Debris collecting in pump housing. Clean pump
housing.
• Too much clearance between impeller and insert.
Pump takes in water, little or
no discharge.
• Engine speed too low. Adjust speed.
• Suction strainer partially plugged. Clean strainer.
• Impeller worn. Adjust clearance by adding shims or
replace impeller.
• Volute insert worn or damaged. Adjust clearance or
replace insert.
Suction hose leaks at inlet.
• Clamps are not sealing properly. Tighten, replace, or
add clamp.
• Hose diameter is too large.
• Hose is damaged.
Discharge hose does not stay
on coupling.
• Pressure may be too high for clamps being used.
Add another clamp.
• Hose kinked or end blocked. Check hose.
Impeller does not turn; pump
is hard to start.
• Impeller jammed or blocked. Open pump cover and
clean dirt and debris from inside of pump housing.
• Impeller and insert binding. Adjust clearance by
removing shim from behind insert.
Содержание PG 3A
Страница 1: ...Operator s Manual Pump PG 3A 5000184874 08 0511 5 0 0 0 1 8 4 8 7 4 EN...
Страница 6: ......
Страница 16: ...Labels PG 3A 16 wc_si000519gb fm 2 Labels 2 1 Label Locations wc_gr000833 A C D E G H F B...
Страница 40: ...Emission Control Systems Information and Warranty 40 wc_tx001753gb fm...
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......