38
Operation
GP 4000
4.16
Voltage Selector
The voltage selector switch
(a)
allows the generator to operate in either single
(120V) or dual voltage (120/240V) mode.
In single-voltage mode, use only the 120V twist-lock
(b)
and duplex receptacles
(c1
,
c2)
. The full rated power of the generator is shared between the three
receptacles.
In dual voltage mode both the 120V and 120/240V receptacles are powered; lower
watts are available on receptacles
(c1
,
c2
,
b)
. The 120/240V twist-lock receptacle
(d)
should be used in dual mode only. To achieve full power in this receptacle it
should be used alone.
NOTICE:
Never switch the voltage selector switch with the main breaker on! This
can cause arcing and can damage the generator. Turn all tools and appliances off
and place main breaker
(e)
in the OFF position before changing voltage switch
position.
wc_gr010941
a
b
c2
c1
d
e
Содержание GP 4000
Страница 1: ...5000192915 02 0813 5 0 0 0 1 9 2 9 1 5 Operator s Manual Portable Generator GP 4000 EN...
Страница 6: ...Foreword GP 4000 6 wc_tx003404gb fm...
Страница 18: ...wc_si000792gb fm 18 Labels GP 4000 2 Labels 2 1 Label Locations wc_gr010975 A B C D E F J K H L G...
Страница 31: ...wc_tx003406gb fm 31 GP 4000 Operation wc_gr010938 a b c d e f g h j k l m n o p 1 l l n...
Страница 50: ...wc_td000566gb fm 50 Technical Data GP 4000 Notes...
Страница 59: ...Emission Control Systems Information and Warranty wc_tx001773gb fm 59...
Страница 60: ...Emission Control Systems Information and Warranty 60 wc_tx001773gb fm...
Страница 61: ...Schematics wc_tx003409gb fm 61 9 Schematics...
Страница 67: ......