background image

wc_si000791gb.fm

17

GP 4000

Safety Information

Cleaning 

When cleaning and servicing the machine:

„

Keep the machine clean and free of debris such as leaves, paper, cartons, etc.

„

Keep the labels legible.

When cleaning the machine:

„

Do not clean the machine while it is running.

„

Never use gasoline or other types of fuels or flammable solvents to clean the 
machine. Fumes from fuels and solvents can become explosive.

  

Personal 

Protective 

Equipment 

(PPE)

Wear the following Personal Protective Equipment (PPE) while servicing or 
maintaining this machine:

„

Close-fitting work clothes that do not hinder movement

„

Safety glasses with side shields

„

Hearing protection

„

Safety-toed footwear

In addition, before servicing or maintaining the machine:

„

Tie back long hair.

„

Remove all jewelry (including rings).

  

Precautions

„

Do not allow water to accumulate around the base of the machine.  If water is 
present, move the machine and allow the machine to dry before servicing.

„

Do not service the machine if your clothing or skin is wet.

„

Always turn the engine off before servicing the machine. If the engine has 
electric start, disconnect the negative terminal on the battery before servicing 
the machine.

„

Always let the engine cool before transporting or servicing the machine.

  

Содержание GP 4000

Страница 1: ...5000192915 02 0813 5 0 0 0 1 9 2 9 1 5 Operator s Manual Portable Generator GP 4000 EN...

Страница 2: ...distribution not authorized by Wacker Neuson Production Americas LLC represents an infringement of valid copyrights Violators will be prosecuted Trademarks All trademarks referenced in this manual are...

Страница 3: ...R use a generator inside homes buildings garages crawlspaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does N...

Страница 4: ...order a replacement or visit www wackerneuson com When ordering parts or requesting service information be prepared to provide the machine model number item number revision number and serial number E...

Страница 5: ...ding spark arresters consult the engine distributor or the local Health and Safety Administrator Manufacturer s approval This manual contains references to approved parts attachments and modifica tion...

Страница 6: ...Foreword GP 4000 6 wc_tx003404gb fm...

Страница 7: ...24 4 1 Preparing the Machine for First Use 24 4 2 Recommended Fuel 25 4 3 Refueling the Machine 26 4 4 Determining Power Requirements 27 4 5 Positioning the Generator for Operation 28 4 6 Wheel Kit 3...

Страница 8: ...Systems Information and Warranty 51 8 1 Emission Control System Background Information 51 8 2 Limited Defect Warranty for Wacker Neuson Emission Control Systems 52 8 3 California Evaporative Emission...

Страница 9: ...personal hazards f Obey all safety messages that follow this symbol DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury f To avoid death or seriou...

Страница 10: ...ts that are incompatible with the generator output Overloading the generator with a load that draws excessive power during either continuous running or start up Operating the generator in a manner tha...

Страница 11: ...INUTES Generator exhaust contains carbon monoxide CO This is a poison you cannot see or smell If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you c...

Страница 12: ...not operate the machine if any safety devices or guards are missing or inoperative Do not modify or defeat the safety devices Only use accessories or attachments that are approved by Wacker Neuson Saf...

Страница 13: ...d earthen ground per national and local regulations Always remove all tools cords and other loose items from the generator before starting it General Safety Do not operate the generator when open cont...

Страница 14: ...reach of children Cleaning When cleaning and servicing the machine Keep the machine clean and free of debris such as leaves paper cartons etc Keep the labels legible When cleaning the machine Do not c...

Страница 15: ...e if fuel leaks are present or the fuel lines are loose Do not run the engine near open flames Do not start the engine if fuel has spilled or a fuel odor is present Move the generator away from the sp...

Страница 16: ...rate the machine with a known problem or deficiency All repairs and adjustments shall be completed by a qualified technician Turn off the machine before performing maintenance or making repairs Remain...

Страница 17: ...aining this machine Close fitting work clothes that do not hinder movement Safety glasses with side shields Hearing protection Safety toed footwear In addition before servicing or maintaining the mach...

Страница 18: ...wc_si000792gb fm 18 Labels GP 4000 2 Labels 2 1 Label Locations wc_gr010975 A B C D E F J K H L G...

Страница 19: ...ing objects near the machine Stop the engine before refueling GFCI TEST INSTRUCTIONS TEST BEFORE EACH USE Normal operating state sensing device green LED is ON and circuit breaker is at ON position St...

Страница 20: ...s equipment meets U S EPA EVAP standards Evaporative Family CW1XNHEQCL2 G Important Emissions Information This equipment meets California EVP emission regulations for small off road engines H Use only...

Страница 21: ...r indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only operate...

Страница 22: ...ical current from the generator to backfeed into utility lines This may result in electrocution of utility workers fire or explosion Connections to a building s electrical system must be made by a qua...

Страница 23: ...ached securely and has enough weight bearing capacity to lift or hold the generator safely Remain aware of the location of other people nearby when lifting the generator Transporting the machine Obser...

Страница 24: ...are breathing CO But even if you cannot smell the exhaust you could be breathing CO f NEVER use a generator inside homes buildings garages crawlspaces or other partly enclosed areas Deadly levels of c...

Страница 25: ...el confirm the fuel s contents Some states and provinces require this information to be posted on the fuel pump The following is the Wacker Neuson approved percentage of oxygenates ETHANOL ethyl or gr...

Страница 26: ...o refuel the machine is now complete WARNING Fire hazard Fuel and its vapors are extremely flammable Burning fuel can cause severe burns f Keep all sources of ignition away from the machine while refu...

Страница 27: ...er or dealer of the tool or appliance with questions regarding its power requirements NOTICE If a tool or appliance does not reach full speed within a few seconds when switched on turn it off immediat...

Страница 28: ...MINUTES Generator exhaust contains carbon monoxide CO This is a poison you cannot see or smell If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you...

Страница 29: ...gs windows doors and vents Also point the engine exhaust away from combustible materials Position the generator on firm level ground so that it will not slide or shift CO Detectors Alarms Install CO d...

Страница 30: ...of the axle and separate the legs of the pins 7 Align the holes found in the leg bracket b to the holes of the lower cross member 8 Insert M6 x 16 screws l through the outer holes on the cross member...

Страница 31: ...wc_tx003406gb fm 31 GP 4000 Operation wc_gr010938 a b c d e f g h j k l m n o p 1 l l n...

Страница 32: ...so affects the cooling capacity of air the higher the altitude the less dense the air is and thus the lower its ability to transfer heat For every increase in altitude of 500 m 1650 ft above 1000 m 33...

Страница 33: ...local agency having jurisdiction over electrical compliance If the generator is used at a construction site there may be additional regulations which must be observed In some areas generators are req...

Страница 34: ...ss Damaged extension cords can cause electrical shock resulting in serious injury or death DO NOT use worn bare or frayed cords Replace damaged cords immediately Use the chart below as a guide for sel...

Страница 35: ...Switch g GFCI test button b Auto Idle Switch h GFCI reset button c Twist lock receptacle 120V j Twist lock receptacle 120 240V d Main Circuit Breaker m 20A circuit breaker CAN only e Voltage Selector...

Страница 36: ...at ON position 1 Press TEST button a Green LED should go OUT and red LED should come ON and circuit breaker should trigger to OFF position b 2 If sensing device LED or breaker does not trip or change...

Страница 37: ...ull speed when a tool or appliance is turned back on To turn the auto idle feature on push the auto idle switch to AUTO The AUTO setting is recommended while the generator is running to minimize fuel...

Страница 38: ...cles In dual voltage mode both the 120V and 120 240V receptacles are powered lower watts are available on receptacles c1 c2 b The 120 240V twist lock receptacle d should be used in dual mode only To a...

Страница 39: ...in the engine drops too low the engine will not start 4 Fill the fuel tank with fresh regular unleaded grade gasoline DO NOT use an oil gas mixture The use of gasohol or any fuel containing more than...

Страница 40: ...main breaker in the OFF position a2 3 Set the Auto Idle Switch c to OFF 4 Open the fuel valve d1 Note If the engine is cold move the choke lever to the closed position e2 If the engine is hot set the...

Страница 41: ...4 Close the fuel valve d2 Note To stop the engine quickly in an emergency turn the engine switch to OFF b2 4 20 Emergency Shutdown Procedure Procedure If a breakdown or accident occurs while the mach...

Страница 42: ...table below lists basic machine and engine maintenance Tasks designated with check marks may be performed by the operator Tasks designated with square bullet points require special training and equipm...

Страница 43: ...environmental protection legislation 3 Install the drain plug 4 Fill the engine crankcase with the recommended oil up to the level of the plug opening c See section Technical Data for oil quantity an...

Страница 44: ...the element b for holes or tears Replace the element if it is damaged 2 Wash the foam element b in a solution of mild detergent and warm water Rinse it thoroughly in clean water Allow the element to d...

Страница 45: ...ine Do not touch the muffler while it is hot Note Refer to section Technical Data for the recommended spark plug type and the electrode gap setting 1 Remove the spark plug and inspect it 2 Replace the...

Страница 46: ...tank in a well ventilated area Do not drain the fuel tank in an area with flames or sparks 3 Loosen the drain screw on the carburetor and drain any remaining fuel from the carburetor 4 Change the eng...

Страница 47: ...ap is tight Engine oil level is adequate If engine starts but there is no power at receptacles check that Circuit breaker is closed Connector from generator to control panel is tight If engine starts...

Страница 48: ...Dual voltage single phase Auto voltage regulator system AC voltages available volts phase 120 240 1 Frequency Hz 60 Power factor 1 0 AC receptacles 125V duplex 125V duplex 125V twist lock 125V 250V t...

Страница 49: ...ke Wacker Neuson Engine model WM 270 Max rated power rated speed kW hp 6 6 9 4000 rpm Spark plug NGK BR 6HS Champion RL86C Electrode gap mm in 0 6 0 7 0 024 0 028 Operating speed rpm 3600 Air cleaner...

Страница 50: ...wc_td000566gb fm 50 Technical Data GP 4000 Notes...

Страница 51: ...time of purchase Exhaust Emissions The combustion process produces carbon monoxide oxides of nitrogen and hydrocarbons Control of hydrocarbons and oxides of nitrogen is very important because under ce...

Страница 52: ...warranted parts during the warranty period Limited Defect Warranty Period for Wacker Neuson Emission Control Systems The warranty period for this engine equipment begins on the date of sale to the ini...

Страница 53: ...al parts Air fuel ratio feedback system if applicable Cold start enrichment system if applicable Regulator assembly if applicable Exhaust system Catalytic muffler if applicable Exhaust manifold if app...

Страница 54: ...sted in the maintenance section of the engine equipment operator s manual such as spark plugs and filters Incidental or consequential damages such as loss of time or the use of the engine equipment or...

Страница 55: ...ill be advised of the appropriate dealer service center where warranty repair can be performed All repairs qualifying under this limited warranty must be performed by an authorized Wacker Neuson deale...

Страница 56: ...d part that is not scheduled for replacement as required maintenance or which is scheduled only for regular inspection to the effect of repair or replace as necessary shall be warranted for two years...

Страница 57: ...en abused neglected or improperly maintained and that such abuse neglect or improper maintenance was the direct cause of the need for repair or replacement of the part That notwithstanding any adjustm...

Страница 58: ...Emission Control Systems Information and Warranty 58 wc_tx001773gb fm 8 4 California Exhaust Emission Control Warranty Statement...

Страница 59: ...Emission Control Systems Information and Warranty wc_tx001773gb fm 59...

Страница 60: ...Emission Control Systems Information and Warranty 60 wc_tx001773gb fm...

Страница 61: ...Schematics wc_tx003409gb fm 61 9 Schematics...

Страница 62: ...AWG 71 BRN 12 AWG LINE LINE ORG ORG 18 18 AWG AWG 102 BRN 102 BRN 5 BRN 5 BRN 43 BLU 16 AWG 43 BLU 16 AWG 72 BRN 72 BRN GRN YEL GRN YEL 42 BLU 42 BLU 73 BRN 73 BRN 40 BLU 40 BLU 70 BRN 12 AWG 70 BRN...

Страница 63: ...D Wacker Neuson Engine B Control box Ref Description Ref Description 1 Main stator winding 1 12 Engine ON OFF switch 2 Main stator winding 2 13 Rectifier 3 Auto idle unit 14 Rotor winding brushes 4 M...

Страница 64: ...N 12 AWG 12 AWG 8 BLU 8 BLU 28 BRN 12 AWG 28 BRN 12 AWG 101 BLU 101 BLU 29 BRN 29 BRN LINE LINE LOAD LOAD ORG ORG 18 18 AWG AWG 5 BRN 5 BRN 102 BRN 102 BRN 43 BLU 16 AWG 43 BLU 16 AWG 20A 20A 24 BRN 2...

Страница 65: ...nding brushes 3 Auto idle unit 15 Secondary excitation winding 4 Main circuit breaker 16 DC winding 5 Voltage selector switch 120 240V position shown 17 Automatic voltage regulator AVR 6 Duplex recept...

Страница 66: ...Ref Description Ref Description A Generator D Wacker Neuson Engine B Control box C Electric start engines GPS Ref Description 1 Idle solenoid 2 Spark plug 3 Oil level sender 4 Oil level switch 5 Coil...

Страница 67: ......

Страница 68: ...02 390 Wacker Neuson Production Americas LLC N92W15000 Anthony Ave Menomonee Falls WI 53051 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Neuson Limited Room 1701 03 1717 20 17 F Tower 1 G...