![Wacker Neuson E09-01 Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/wacker-neuson/e09-01/e09-01_operators-manual_3129865131.webp)
BA 1404 en – Edition 2.7 * 1404b510.fm
5-3
Maintenance
Draining the fuel
Danger
!
All work involving fuel carries an increased
Fire and poisoning hazard!
☞
Do not work in closed rooms
☞
Never perform work on the fuel system near open flames or sparks
☞
No smoking, no fire!
Environment!
Use a suitable container to collect the fuel as it drains and dispose of it in an environmen-
tally friendly manner!
Filler inlet
A
for the fuel tank is located in the engine compartment, on the left in driving
direction.
Proceed as follows:
☞
Open filler inlet
A
☞
Pump out the fuel with a suitable pump
➥
Collect the fuel in a suitable container
Stationary fuel pumps
General
Only refuel from stationary fuel pumps. Fuel from barrels or cans is usually dirty.
Even the smallest particles of dirt can cause
• Increased engine wear
• Malfunctions in the fuel system and
• Reduced effectiveness of the fuel filters
Refueling from barrels
If refuelling from barrels is unavoidable, please note the following (see Fig. 182):
• Barrels must neither be rolled nor tilted before refueling
• Protect the suction pipe opening of the barrel pump with a fine-mesh screen
• Immerse the suction pipe opening down to a max. of 15 cm (6 in) above the bottom of
the barrel
• Only fill the tank using refueling aids (funnels or filler pipes) with an integral microfilter
• Keep all refueling containers clean at all times
Abb. 181: Fuel tank
A
Incorrect
Correct
Abb. 182: Refueling from a barrel
Содержание E09-01
Страница 8: ...1 6 BA 1404 en Edition 2 7 Ba1404en2_7IVZ fm Table of contents...
Страница 23: ...BA 1404 en Edition 2 7 1404b110 fm 1 13 Introduction Overview of safety labels...
Страница 171: ...BA 1404 en Edition 2 7 1404b560 fm 5 43 Maintenance DIN 51 502 DIN 51 825 1000156007 1...
Страница 172: ...5 44 BA 1404 en Edition 2 7 1404b560 fm Maintenance...