ZTA9648O

Counter/Rate Meter

User manual

Содержание ZTA9648O

Страница 1: ...ZTA9648O Counter Rate Meter User manual...

Страница 2: ......

Страница 3: ...3 5 1 b Serial COM1 Modbus slave 13 5 1 c DI 1 digital input 13 5 1 d DI 2 digital input 14 5 1 e DI 3 digital input 14 5 1 f DI 4 digital input 14 5 1 g Sensor power output 12 24Vdc 15 5 1 h Q1 Relai...

Страница 4: ...emory card 33 10 4 a Creation memory card 33 10 4 b Loading configuration from memory card 34 11 Table of configuration parameters 34 11 1 Display 34 11 2 Digital input 1 2 36 11 3 Digital input 3 4 3...

Страница 5: ...es should be avoided Device is not conceived for applications related to nuclear power plants weapon systems flight control mass transportation systems Only qualified personnel should be allowed to us...

Страница 6: ...roduct Not doing so may occasionally result in unexpected events Do not handle the Digital Controller in ways that exceed the ratings The product is designed for indoor use only Do not use or store th...

Страница 7: ...a disconnecting means for the controller The device must be protected by a fuse 1A cl 9 6 2 Wipe off any dirt from the Digital Controller with a soft dry cloth Never use thinners benzine alcohol or an...

Страница 8: ...1 RS485 Rfid communication 3 Technical data 3 1 General data Display 2 42 monochrome yellow OLED graphical display Operating temperature Temperature 0 40 C Humidity 35 95 uR Max altitude 2000m Sealin...

Страница 9: ...for sensor and digital inputs power supply selectable by parameter 12Vdc 24Vdc Outputs 2 relais Q1 Q2 Contacts 2 A 250 Vac Resistive load 1 8Hp 2 digital outputs Q3 Q4 PNP 12 24 Vdc Outputs Digital in...

Страница 10: ...ter values are all 64 bit Range of 32 bit variables 2 147 483 648 2 147 483 647 Range of 64 bit variables 9 223 372 036 854 775 808 9 223 372 036 854 775 807 Configuration display of data For each dat...

Страница 11: ...COUNTER 1 count 0 10 SETPOINT 1 1 2 3 4 count Memory Card USB optional SFUR0USB Frontal panel cut out 45 x 91 mm Suggested thickness 2 8 mm 48 mm 10 48 mm 96 mm 5 5 Electrical wirings This device is d...

Страница 12: ...ant manufacturer from the safety and compliance obligations of the machine as a whole To wire terminals 1 6 use crimped tube ferrules or flexible or rigid copper wire between 0 2 and 2 5 mm min AWG24...

Страница 13: ...rminal I1 13 must remain free Activation Vi 3 7V Deactivation Vi 3 7V PNP configuration to activate the input short circuit terminals I1 13 and 12 24 Vdc 10 Terminal I1 7 must remain free Activation V...

Страница 14: ...V 16 Encoder B B Line driver configuration input provides for the connection of two complementary signals read in differential mode Signal B positive is connected to terminal I2 8 Signal B negative is...

Страница 15: ...Depending on the supply voltage and output setting the deliverable currents are as follows Supply OUT 12Vdc OUT 24Vdc 24 Vdc 50 mA 20 mA 24 Vac 50 mA 20 mA 115 Vac 50 mA 50 mA 230 Vac 50 mA 50 mA 5 1...

Страница 16: ...s follows Supply OUT 12Vdc OUT 24Vdc 24 Vdc 25 mA 5 mA 24 Vac 25 mA 5 mA 115 Vac 25 mA 25 mA 230 Vac 25 mA 25 mA 5 1 k Q4 Digital ouput Q4 0V 17 16 When activated the PNP digital output provides a pos...

Страница 17: ...e multilingual interface makes navigation and access to various features intuitive Sel English Italiano Deutsch Fran ais Espa ol At first starting display shows language selection 6 3 Display mode 123...

Страница 18: ...HOMETER 13110 2 HZ OUTPUT DURATION 5 0 S Displays the first four enabled data value with its description and unit of measurement In this type of display the outputs status is visible in a dedicated sc...

Страница 19: ...the keyboard buttons during normal variable display will display the navigation menu at the buttons Pushing and you can scroll forward and backward through the variable display screens The bottom of...

Страница 20: ...1 COM1 Q2 Q3 Q4 This screen displays the active disactive status of each digital input output and communication related to the serial port COM1 8 COM1 Serial Communication The ZTA9648O has serial COM1...

Страница 21: ...mory after exceeding the allowed number of writing cycles NB Changes made to word other than those shown in the table below may cause malfunction of the device FeaturesModbusRTUslaveprotocol Baud rate...

Страница 22: ...aracters used Each parameter 32 bits contains 4 characters each character 8 bits so to store strings with more than 4 characters multiple contiguous parameters are used based on the number of characte...

Страница 23: ...cuted the device restart to allow proper initialization R W 0 600 Counter value 1 H 32 bit format bit 31 16 RO 601 Counter value 1 L 32 bit format bit 15 0 RO 602 Counter counts 1 H 32 bit format bit...

Страница 24: ...633 Counter counts 2 L 32 bit format bit 15 0 RO 634 Direction status lock hold counter 2 Bit 0 Direzione 0 Up 1 Down Bit 1 Lock 0 Unlock 1 Lock Bit 2 Hold 0 Update 1 Hold RO 0 635 Counter direction...

Страница 25: ...er hold function enabled RO 0 709 Rate Meter hold value H RO 710 Rate Meter hold value L RO 720 Serial command Rate Meter 0 No command 1 Command enable disable tachmeter outputs 2 Command enable disab...

Страница 26: ...bit format bit 47 32 RO 815 Counter hold value 1 LH 64 bit format bit 31 16 RO 816 Counter hold value 1 LL 64 bit format bit 15 0 RO 820 Serial command counter 1 0 No command 1 Load command 2 Command...

Страница 27: ...and executed RO 0 843 Counter hold value 2 HH 64 bit format bit 63 48 RO 844 Counter hold value 2 HL 64 bit format bit 47 32 RO 845 Counter hold value 2 LH 64 bit format bit 31 16 RO 846 Counter hold...

Страница 28: ...error Bit 6 Parameter out of range Bit 7 FRam memory access error RO 0 2001 Parameter 1 H R W EEPROM 2002 Parameter 1 L R W EEPROM 2003 Parameter 2 H R W EEPROM 2004 Parameter 2 L R W EEPROM 2597 Par...

Страница 29: ...29 Modbus Address Description Read Write Resetvalue 4600 Parameter 300 L R W EEPROM Parameters changed using serial addresses 4001 to 4600 are saved in the Eeprom only after 10 from the last write of...

Страница 30: ...ameters Incorrect status data Detected an error in the device status save data Eeprom read error An error was detected in the Eeprom memory read sequence Err eeprom write An error was detected in the...

Страница 31: ...he names of the parameter groups 5 Sel to enter parameter group Shows the parameters of the selected group Press and to select parameter to be modified 6 Sel to enter parameter modification Shows all...

Страница 32: ...materials between the phone and the device ex aluminium cover or with magnetic stand It is useful to eneable the system sounds on the smartphone as the notification sound confirms that the device has...

Страница 33: ...he new written modifications if it does not restart the ZTA9648O will continue to work with the previous configuration In addition to the classic operation of parameters reading modification wri ting...

Страница 34: ...he operation without changing current configuration 11 Table of configuration parameters Below is the complete list of parameters divided into various subgroups 11 1 Display Display and visualisation...

Страница 35: ...or rate meter changes faster than this interval the displayed value in each case will not be updated before this interval expires 0 1 5 0 s Default 0 1 s 5 Contrast Determines the contrast value for t...

Страница 36: ...Load count 1 2 11 2 Digital input 1 2 Parameters to configure digital input 1 and 2 dedicated to counting 31 Hardware type 36 Hardware type Selects the digital input hardware type NPN Input suitable...

Страница 37: ...Active status Selects input signal active state Up front Default Counting action will take place on the input signal up front Down front Counting action will take place on the input signal down front...

Страница 38: ...take place on the input signal down front High level Action will take place on the input signal high level Low level The action will take place on the inout signal low level 45 Input function 50 Input...

Страница 39: ...es the rate meter hold function 11 4 Counter 1 2 Counter 1 and 2 configuration parameters 58 Clock sorgent Counter 1 78 Clock sorgent Counter 2 Select the counting source of counter Disabled Default 2...

Страница 40: ...wn decrease mode from input I2 I1 Up I2 In Dec H I1 L I2 H L n 1 n 2 n 2 n 1 n 1 1 1 1 Counter count derives from input I1 Input I2 switches from Up increment to Down decrement counting mode I1 Up I2...

Страница 41: ...f the counter display or activates the hold function of the current counter value I1 Down I2 Off H I1 L n 4 n 3 n 2 n 1 n 1 1 1 1 Counter count in Down decrement mode derives from input I1 Input I2 re...

Страница 42: ...on of the current counter value I1 Off I2 Up H I2 L n n 1 n 2 n 3 n 4 1 1 1 1 Counter count in Up increment mode comes from input I2 Input I1 remains free for other uses I1 Off I2 Down H I2 L n 4 n 3...

Страница 43: ...e occurs each time output Q4 is activated 51 Description Counter 1 71 Description Counter 2 Defines the counter description text string max 16 characters that will be displayed together with the count...

Страница 44: ...vide the counter count value into a rescaled value useful for display 1 99999 Default 1 Set the correct divisor value which in combination with the Multiplier allows a rescaled value to be obtained fr...

Страница 45: ...ed when the value reaches the value Set3 Out duration 3 Counter Set3 Out duration 3 Set4 Out duration 4 Counter is automatically loaded when the value reaches the value Set4 Out duration 4 Counter Set...

Страница 46: ...ses are detected for more than 100ms This implies that a running switch off i e during the counting phase may not guarantee the integrity of the stored data At switch on the counter is preloaded with...

Страница 47: ...culate the mathematical average 100 Acquisition mode Defines frequency acquisition mode used Mode 1 Default 1 Frequency is determined by measuring each pulse period duration 101 Multiplier Sets the va...

Страница 48: ...ecimal digit 0 00 2 decimal digits 0 000 3 decimal digits 0 0000 4 decimal digits 0 00000 5 decimal digits 0 000000 6 decimal digits 105 Fixed zeros Defines the number of least significant digits that...

Страница 49: ...n the event of a power failure The minimum peak is initialised with value 0 Minimum peak Only minimum peak value is retained even in the event of a power failure The maximum peak is initialised with v...

Страница 50: ...alue SET 1 0 Out Counter Load 1 0 Counter Value Output is active when counter value is at the setpoint Count Set Od T Time COUNTER LoadValue SET 1 0 Out Counter Load Output Duration Time 1 0 Counter V...

Страница 51: ...s at the setpoint Count Set Od C Time COUNTER LoadValue SET 1 0 Out Counter Load 1 0 Counter Value Output Duration Counts Output is active when counter value is at the setpoint and is deactivated when...

Страница 52: ...utputQ2 175 Output enable OutputQ3 205 Output enable OutputQ4 Defines the output activation mode These parameters are only visible if the corresponding Source Value parameter is set to Rate meter Alwa...

Страница 53: ...ation delay Auto Logic Output 1 0 Latch 1 0 Pulse Tach Value Pulse duration time Clear by Input Time Tach Value SET Output is active in case of downward deviation The rate meter value falls below the...

Страница 54: ...s the output activation duration These parameters are visible only if the corresponding Source Value parameter is set to Rate meter 1 Automatic Default Output reset occurs automatically as soon as the...

Страница 55: ...efines the band value related to output management in case management in In band or Out band mode is selected These parameters are visible only if the corresponding parameter Source Value is set to Ra...

Страница 56: ...number takes formatting from the source data to which it refers 128 Upper limit Output Q1 158 Upper limit Output Q2 188 Upper limit Output Q3 218 Upper limit Output Q4 Defines the setpoint value input...

Страница 57: ...ute Relative to Q1 Relative to Q3 Relative to Q4 Options for Output Q3 are the following Absolute Relative to Q1 Relative to Q2 Relative to Q4 Options for Output Q4 are the following Absolute Relative...

Страница 58: ...1 e Q2 Output normally actived Q3 e Q4 11 7 Output setting Parameters to manage the voltage output for supply inputs and sensors and digital outputs Q3 and Q4 231 Output voltage Defines the output vol...

Страница 59: ...aud 39 400 baud 57 600 baud Default 115 200 baud 293 Serial format Selects the format for serial communication 8 N 1 Default 8 bit No parity 1 Stop bit 8 E 1 8 bit Even parity 1 Stop bit 8 O 1 8 bit O...

Страница 60: ...60 ZTA9648O User manual Note Updates...

Страница 61: ......