6.4.1 Parameterization via Configuration Assembly
A one-time parameterization of the encoder can be carried out by means of the
configuration assembly. The parameters are only adopted when a new connection is
established, i.e. the config. assembly is not to be used during ongoing operation.
•
After you have performed the one-time parameterization with
the config. assembly, it is recommended to remove it again.
First open the "Module Properties" of the previously created device. Then select the
"Change ..." button in the "General" window. Now select the connection "Input Only
(101+110)" under "Connections" and confirm with "OK".
Figure 6.21: Module definition
This loads the assemblies 101 and 110 into the controller tags. Assembly 101 is used
to view the process data, while Assembly 110 is used for configuration.
Now navigate to the controller tags. Under "WDGA_EP:C" you will find the parameters
to be set.