Technical Manual
WDGA with CANopen-Interface
8 - Setting-up the encoder
© Wachendorff Automation GmbH & Co. KG
67
Rev.1.24
Now the cam-high-limits 1, 2, and 3 can be set as in the table above:
CAM 1 = 2048 = 0800h
600h+ID 8
23h
20h
63h
01h
00h
08h
00h
00h
CAN-ID
DLC Command Object
L
Object
H
Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.69: CAM-High-Limit 1
CAM 2 = 4095 = 0FFFh
600h+ID 8
23h
21h
63h
01h
FFh
0Fh
00h
00h
CAN-ID
DLC Command Object
L
Object
H
Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.70: CAM-High-Limit 2
CAM 3 = 682 = 02AAh
600h+ID 8
23h
23h
63h
01h
AAh
02h
00h
00h
CAN-ID
DLC Command Object
L
Object
H
Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.71: CAM-High-Limit 3
The setting of the CAM-Low-Limits 1, 2 und 3 is similar:
CAM 1 = 0 = 00h
600h+ID 8
23h
10h
63h
01h
00h
00h
00h
00h
CAN-ID
DLC Command Object
L
Object
H
Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.72: CAM-Low-Limit 1
CAM 2 = 2049 = 0801h
600h+ID 8
23h
11h
63h
01h
01h
08h
00h
00h
CAN-ID
DLC Command Object
L
Object
H
Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.73: CAM-Low-Limit 2
CAM 3 = 0 = 00h
600h+ID 8
23h
12h
63h
01h
00h
00h
00h
00h
CAN-ID
DLC Command Object
L
Object
H
Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.74: CAM-Low-Limit 3
In our example the CAM-Hysteresis shall be 0, so there is no change necessary.
With the CAM-Polarity-Register the polarity of the cams can be inverted.
Using object 6300h Sub-Index 1 the CAM-state-register can be read. The CAM-state-
register is also PDO mappable! For more details see 7.5.1 CAM-state-register. To save
the configuration into the EEPROM, see 8.12.1 "Saving parameters into EEPROM”.
Содержание WDGA CANopen
Страница 1: ...R e v 1...