4.3.4.29
6501h
– Single-turn resolution
Object 6501h can be used to read out the maximum number of increments per
revolution. (Single-turn resolution)
4.3.4.30
6502h
– Number of distinguishable revolutions
Object 6502h can be used to read out the maximum number of distinguishable
revolutions. (Multi-turn resolution)
4.3.4.31
6503h
– Alarms
Object 6503h shows a possible position error (see Table 4.34)
15(MSB) … 1 0(LSB)
Always 0
Bit 0 = 1: Position error
An error has occurred in the sensor. The position value is incorrect.
Table 4.34: 6503h
– Alarms
4.3.4.32
6504h
– Supported alarms
Object 6504h shows the supported alarms. Only the position error is supported,
therefore the value is always 0x0001h.