Technical Manual
WDGA with EtherCAT
4 - EtherCAT
© Wachendorff Automation GmbH & Co. KG
18
Rev.1.09
Object Name
Idx
Description
Data size
(bit)
ro
rw
co
Map
Default
1A01h
2nd TPDO
mapping
parameter
00h Defines the PDO
mapping for the 2nd
TPDO
Unsigned8
rw
no
06h
01h 1st Output object
Default object: 6008h
High-resolution
position value
Unsigned32
rw
6008 0030h
02h 2nd Output object,
Default: 6030h Speed
Unsigned32
rw
6030 0110h
03h 3rd Output object,
Default: 6503h
Alarms
Unsigned32
rw
6503 0010h
04h 4th Output object,
Default: 6505h
Warnings
Unsigned32
rw
6505 0010h
05h 5th Output object,
Default: 6300h CAM
state
Unsigned32
rw
6300 0108h
06h 6th Output object,
Default: 6410h High-
resolution work area
state
Unsigned32
rw
6410 0108h
Inactive
through sub-
index 00h
07h
to
08h
Mapping of object 7-8
in the application
Unsigned32
rw
0000 0000h
1C00h Sync
Manager
Communi-
cation Type
00h Sync Manager
Configuration of
communication
channels
Unsigned8
ro
no
04h
01h Communication type
SM0
Unsigned8
ro
01h
02h Communication type
SM1
Unsigned8
ro
02h
03h Communication type
SM2
Unsigned8
ro
03h
04h Communication type
SM3
Unsigned8
ro
04h
Table 4.5: Object directory 1A01h - 1C00h