5.11 Yesterday’s energy usage display.
The energy usage of the control yesterday can be displayed temporarily.
1.
Press MENU until Hrs use and yesterday’s DAY icons are displayed.
2.
The energy usage in hours and minutes is displayed in the time area.
3.
Press OK to return to normal operation.
5.12 Last weeks energy usage display.
The energy usage of the control during the previous seven days can be displayed temporarily.
1.
Press MENU until Hrs use and all seven DAY icons are displayed.
2.
The energy usage in hours is displayed in the time area.
3.
Press OK to return to normal operation.
5.13 Total energy usage display.
The total energy usage of the control can be displayed temporarily.
1.
Press MENU until Hrs use icon is displayed.
2.
The energy usage in hours is displayed in the time area.
3.
Press OK to return to normal operation.
5.14 Total energy usage clear.
The total energy usage of the control can be cleared back to 0000.
1.
Press MENU until Hrs use icons are displayed along with clr in the time area.
2.
Press OK to reset the total energy usage and return to normal operation.
6. User controls.
Various buttons allow the user to adjust the control.
If the control has been PIN protected then when any of the buttons
S
,
T
, O/I, 24h are pressed the PIN entry routine will be presented, as in section 5.1,
before the user can continue.
6.1 Enter PIN (PIN enabled only).
1.
Press MENU to access settings menu. The PADLOCK icon and 0000 are displayed.
2.
The first 0 will be displayed flashing.
3.
Adjust PIN digit 1 using
S
and
T
.
4.
Press OK to accept digit 1. The second 0 will be displayed flashing.
5.
Adjust PIN digit 2 using
S
and
T
.
6.
Press OK to accept digit 2. The third 0 will be displayed flashing.
7.
Adjust PIN digit 3 using
S
and
T
.
8.
Press OK to accept digit 3. The fourth 0 will be displayed flashing.
9.
Adjust PIN digit 4 using
S
and
T
.
10.
Press OK to accept digit 4. If the PIN entered is incorrect the control will return to normal operation but if the PIN is correct then the user
adjustment will be accessed and remain accessible for 4 minutes.
6.2 Temperature adjustment (un-timed mode only).
The control temperature is adjusted using the
S
and
T
buttons. If the tamper lock has been set then this needs to be cleared before the adjustment can be
made and reset after the adjustment.
Note: the temperature adjustment is from the current measured floor or room temperature (not the set temperature). This is so that the adjustment is
relevant to the current environment being experienced not what it ought to be. For example if the room temperature is set as 20°C but the room has only
reached 15°C when the adjustment is made then the user might not appreciate that the temperature is still to increase and would thus overheat the room if
the adjustment was made from 20°C instead of 15°C.
6.2.1 Floor sensor only operation temperature adjustment.
1.
Press
S
or
T
and the current floor temperature will be displayed flashing with the FLOOR THERMOMETER icon.
2.
Adjust the temperature up or down as required.
3.
Press OK to complete the adjustment and return to normal operation with the current floor temperature displayed but with the revised floor
temperature target.
6.2.2 Floor and room sensor/room sensor only operation temporary temperature adjustment.
1.
Press
S
or
T
and the current room temperature will be displayed flashing with the THERMOMETER icon.
2.
Adjust the temperature up or down as required.
3.
Press OK to complete the adjustment and return to normal operation with the current room temperature displayed but with the revised room