background image

Vysa-Therm™ 3000: 000807  

Vysal Limited. Unit 3 Lovett Farm, Little Somerford, Wiltshire, SN15 5BP. Tel : 01666 822059 Fax: 01666 822422 

Email: [email protected]     Web: www.floor-heating.co.uk  

3.10 PIN protection. 

 

For applications where the occupant should not be able to adjust the control access can be protected by PIN entry. The PIN is set under the engineer 

settings, access to the engineer settings is not protected by the PIN. 

 

If the PIN is left at 0000 or set to 0000 at a later date then no PIN entry is required. 

 

Once a PIN has been set access to the user settings menu, temperature changes using  

S

 and 

T

, O/I button and 24h button is protected by the PIN. 

 

3.11 Floor sensor only temperature display. 

 

When floor sensor only is selected the temperature display can be changed from showing °C to a scale of 0 to 13. The scale will display temperatures using 

the following conversion: 

 

15.6°C and below 

15.8°C to 18.0°C 

18.2°C to 20.4°C 

20.6°C to 22.8°C 

23.0°C to 25.2°C 

25.4°C to 27.6°C 

27.8°C to 30.0°C 

30.2°C to 32.4°C 

32.6°C to 34.8°C 

35.0°C to 37.2°C 

10 

37.4°C to 39.6°C 

11 

39.8°C to 42.0°C 

12 

42.2°C to 44.4°C 

13 

44.6°C and above 

 

Therefore when the maximum floor temperature is set to 28°C (using the DIL switch) the scale will be 0 to 6 and when the maximum floor temperature is 

set to 35°C (using the DIL switch) the scale will be 0 to 9. Other maximum floor temperatures set using the configuration menu will have other ranges. 

 

4. Engineer Settings 

 

A number of features can be set by the installer or user under Engineer Settings. 

 

To access Engineer Settings press and hold the OK button then press the MENU button also. Then press the MENU button until the appropriate icons for 

the item to be changed are shown on the display, the variable being changed will be shown flashing ready for adjustment. 

 

If the user stops programming part way through a process then after 1-minute the control will automatically return to normal operation. Settings changed up 

to that point will have been saved. 

 

The MENU button presents the settings in the following order: 

 

 

Set maximum floor temperature 

 

Set sensor setting  

 

Set timed/un-timed setting  

 

Set program day mode (timed mode only) 

 

Set temperature display mode (floor sensor only control mode) 

 

Set PIN code 

 

Reset to default 

 

4.1 Maximum floor temperature. 

 

The maximum floor temperature applicable to the type of floor can be adjusted from the value selected by the DIL switch setting. 

 

1.

 

Press MENU until Set and FLOOR THERMOMETER and Max icons are displayed. 

2.

 

Maximum floor temperature will be flashing. 

3.

 

Adjust temperature using 

S

 and 

T

4.

 

Press OK to accept maximum floor temperature and advance to next item in Engineer Menu. 

 

4.2 Sensor configuration. 

 

The sensor configuration can be changed from the configuration selected by the DIL switch setting. 

 

Sensor configuration is shown in the time area as C: FA for floor sensor and room (ambient) sensor operation, as C: F for floor sensor only operation  

and as C: A for room (ambient) sensor only operation. 

 

1.

 

Press MENU until Set icon and C: in the time area are displayed. 

2.

 

Sensor configuration as set by DIL switch will be flashing. 

3.

 

Adjust sensor configuration using 

S

 and 

T

4.

 

Press OK to accept sensor configuration and advance to next item in Engineer Settings 

 

 

 

 

Содержание Vysa-Therm 3000

Страница 1: ...ng to open the control When timed operation is chosen the control uses a real time clock and timer periods to change the temperature between the comfort temperature and the savings temperature When un timed operation is chosen the control is set to the required temperature using S and T and controls to this temperature until it is manually adjusted OWNERS MANUAL Vysa Therm 3000 Electrical and elec...

Страница 2: ...to meet your own requirements 5 1 Enter PIN security code PIN Enabled 5 2 Set the tamper lock PIN not enabled 5 3 Floor temperature display Room and floor sensor only 5 4 Set timer periods Timer operation only 5 4 1 Set timer periods 1 day mode 5 4 2 Set timer periods 5 2 day mode 5 4 3 Set timer periods 7 day mode 5 5 Set comfort temperature 5 6 Set savings temperature 5 7 Set minimum floor tempe...

Страница 3: ...d 2 savings temperature starts 12 00 Timer period 3 comfort temperature starts 12 00 Timer period 4 savings temperature starts 23 00 2 3 Temperatures Default sensor mode is floor sensor only control from DIL switches Default temperature display mode is C Frost temperature is fixed as 5 C this is the floor or air temperature Savings temperature floor sensor only mode 20 C floor temperature Savings ...

Страница 4: ...day mode the days are grouped into weekdays and weekends and one set of timer periods apply to all week days Monday Tuesday Wednesday Thursday and Friday whilst another set of timer periods apply to all weekend days Saturday and Sunday In 7 day mode each day has its own set of timer periods and each can be different All timer period configurations offer 4 timer periods per day 3 4 Maximum floor te...

Страница 5: ...der Engineer Settings To access Engineer Settings press and hold the OK button then press the MENU button also Then press the MENU button until the appropriate icons for the item to be changed are shown on the display the variable being changed will be shown flashing ready for adjustment If the user stops programming part way through a process then after 1 minute the control will automatically ret...

Страница 6: ...igit 1 using S and T 4 Press OK to accept digit 1 The second 0 will be displayed flashing 5 Adjust PIN digit 2 using S and T 6 Press OK to accept digit 2 The third 0 will be displayed flashing 7 Adjust PIN digit 3 using S and T 8 Press OK to accept digit 3 The fourth 0 will be displayed flashing 9 Adjust PIN digit 4 using S and T 10 Press OK to accept digit 4 and advance to next item in configurat...

Страница 7: ... to 24 00 Timer period 4 timer period 3 to 24 00 This range of times gives flexibility to programming in particular if timer period 2 and timer period 3 are set as the same time then effectively there is only one comfort period for that day beginning at timer period 1 and ending at timer period 4 5 4 1 Set timer periods 1 day mode In 1 day mode the day icons are not used when setting timer periods...

Страница 8: ...ntil Set and MOON and THERMOMETER icons are displayed If floor sensor only operation then the FLOOR THERMOMETER icon is displayed 2 Savings temperature will be flashing 3 Adjust temperature using S and T 4 Press OK to accept savings temperature and return to normal operation 5 7 Set minimum floor temperature floor sensor enabled only 1 Press MENU until Set and FLOOR THERMOMETER and Min icons are d...

Страница 9: ...ng 5 Adjust PIN digit 2 using S and T 6 Press OK to accept digit 2 The third 0 will be displayed flashing 7 Adjust PIN digit 3 using S and T 8 Press OK to accept digit 3 The fourth 0 will be displayed flashing 9 Adjust PIN digit 4 using S and T 10 Press OK to accept digit 4 If the PIN entered is incorrect the control will return to normal operation but if the PIN is correct then the user adjustmen...

Страница 10: ... operate the heater whatever the temperature When this mode is set only OFF is shown in the time display To set off mode press the O I button twice and OFF is displayed flashing in the time area Press OK to accept this mode To clear frost protection or off modes just press the O I button and normal control will resume 6 5 Constant comfort or savings temperature control timed mode only The control ...

Страница 11: ... drain only occurs when the control is disconnected from the 240V mains supply with the battery in situ Its purpose is to maintain the time and date settings correctly until the control is installed or during power cuts At all other times when the 240 V mains supply is connected there is no current drain to cause the battery life to deteriorate We recommend changing the Coin Battery when the bad b...

Страница 12: ...ation stored in non volatile EEPROM memory Connections 7 by 4 0 mm rising clamp screw terminal Live in Neutral in Live to load Neutral to load Earth no internal connection floor sensor signal floor sensor return Keypad buttons 6 silicon rubber S T OK MENU 24h O I LCD custom 16mm x 30mm 60 segment reflective no backlight see appendix DIL switch setting of operating modes by installer Switch 1 floor...