9. Electrical and electronic specifications. 

 

Supply Voltage: 230 Vac nominal (operating range 200 to 260 Vac), 50/60 Hz 

Standby power consumption: 500 mW 

Relay rating: 16 A resistive (4 A inductive), 230 Vac, 3600 W 

 

Ambient operating temperature: 0 to 35 °C 

Room sensor control set point range: 5 to 35 °C 

Room sensor display and setting resolution: 0.2 °C 

Room sensor operating differential: 0.4 °C 

Room sensor accuracy: ± 1.5 °C over range 10 to 30 °C 

Room sensor: built in NTC thermistor 

Floor sensor control set point range: 5 to 45 °C 

Floor sensor display and setting resolution: 0.2 °C 

Floor sensor operating differential: 1.0 °C 

Floor sensor accuracy: ± 2.0 °C over range 10 to 40 °C 
Floor sensor: NTC thermistor, resistance 10k

 @25 °C 

Floor sensor: the length of the floor sensor lead can be extended up to a maximum of 20 m. 

 

Clock: crystal controlled with time and date plus automatic summer time correction 

Clock accuracy: ± 25 PPM (parts per million) 

Clock battery backup: replaceable lithium coin cell (Type CR2032) 

 

Timer program, settings and configuration stored in non volatile EEPROM memory 

 

Connections: 7 by 4.0 mm² rising clamp screw terminal  

(Live in, Neutral in, Live to load, Neutral to load, Earth - no internal connection, floor sensor signal, floor sensor return) 

 

Keypad buttons: 6 silicon rubber (

S

T

, OK, MENU, 24h, O/I) 

 

LCD: custom, 16mm x 30mm, 60 segment, reflective (no backlight) - see appendix. 

 

DIL switch setting of operating modes by installer 

Switch 1, floor sensor maximum temperature select: on=28°C (wood floor), off=35°C (tiled floor) 

Switch 2, room sensor operation select: on=use room sensor, off=do not use room sensor 

Switch 3, floor sensor operation select: on=use floor sensor, off=do not use floor sensor 

Switch 4, timed operation select: on=timed operation, off=un-timed operation 

 

The wiring requirements for the Vysa-Therm™ 3000 are printed on the reverse of the thermostat above the terminal connections.  

 

The floor sensor and the cold tail leads must not be placed in the same conduit.  

 

If the heating load exceeds the thermostats 16A switching capacity then the heating will be required to be connected via a contactor of sufficient rating. In this 

case terminal 4 becomes the live terminal to switch the contactors coil.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear of the thermostat showing the identification markings.  

1 2  3 4 

5 7 

Mains input 

230 V ~ 50 Hz 

 

Heating 

Load

Floor Sensor 

10K

 NTC 

Thermistor 

Maximum load:  resistive 16 A 

www.floor-heating.co.uk 

Vysa-Therm™ 3000

Earth 

 

L

IP 31 

 

T 35 

 

VYSAL

® 

Содержание Vysa-Therm 3000

Страница 1: ...ng to open the control When timed operation is chosen the control uses a real time clock and timer periods to change the temperature between the comfort temperature and the savings temperature When un timed operation is chosen the control is set to the required temperature using S and T and controls to this temperature until it is manually adjusted OWNERS MANUAL Vysa Therm 3000 Electrical and elec...

Страница 2: ...to meet your own requirements 5 1 Enter PIN security code PIN Enabled 5 2 Set the tamper lock PIN not enabled 5 3 Floor temperature display Room and floor sensor only 5 4 Set timer periods Timer operation only 5 4 1 Set timer periods 1 day mode 5 4 2 Set timer periods 5 2 day mode 5 4 3 Set timer periods 7 day mode 5 5 Set comfort temperature 5 6 Set savings temperature 5 7 Set minimum floor tempe...

Страница 3: ...d 2 savings temperature starts 12 00 Timer period 3 comfort temperature starts 12 00 Timer period 4 savings temperature starts 23 00 2 3 Temperatures Default sensor mode is floor sensor only control from DIL switches Default temperature display mode is C Frost temperature is fixed as 5 C this is the floor or air temperature Savings temperature floor sensor only mode 20 C floor temperature Savings ...

Страница 4: ...day mode the days are grouped into weekdays and weekends and one set of timer periods apply to all week days Monday Tuesday Wednesday Thursday and Friday whilst another set of timer periods apply to all weekend days Saturday and Sunday In 7 day mode each day has its own set of timer periods and each can be different All timer period configurations offer 4 timer periods per day 3 4 Maximum floor te...

Страница 5: ...der Engineer Settings To access Engineer Settings press and hold the OK button then press the MENU button also Then press the MENU button until the appropriate icons for the item to be changed are shown on the display the variable being changed will be shown flashing ready for adjustment If the user stops programming part way through a process then after 1 minute the control will automatically ret...

Страница 6: ...igit 1 using S and T 4 Press OK to accept digit 1 The second 0 will be displayed flashing 5 Adjust PIN digit 2 using S and T 6 Press OK to accept digit 2 The third 0 will be displayed flashing 7 Adjust PIN digit 3 using S and T 8 Press OK to accept digit 3 The fourth 0 will be displayed flashing 9 Adjust PIN digit 4 using S and T 10 Press OK to accept digit 4 and advance to next item in configurat...

Страница 7: ... to 24 00 Timer period 4 timer period 3 to 24 00 This range of times gives flexibility to programming in particular if timer period 2 and timer period 3 are set as the same time then effectively there is only one comfort period for that day beginning at timer period 1 and ending at timer period 4 5 4 1 Set timer periods 1 day mode In 1 day mode the day icons are not used when setting timer periods...

Страница 8: ...ntil Set and MOON and THERMOMETER icons are displayed If floor sensor only operation then the FLOOR THERMOMETER icon is displayed 2 Savings temperature will be flashing 3 Adjust temperature using S and T 4 Press OK to accept savings temperature and return to normal operation 5 7 Set minimum floor temperature floor sensor enabled only 1 Press MENU until Set and FLOOR THERMOMETER and Min icons are d...

Страница 9: ...ng 5 Adjust PIN digit 2 using S and T 6 Press OK to accept digit 2 The third 0 will be displayed flashing 7 Adjust PIN digit 3 using S and T 8 Press OK to accept digit 3 The fourth 0 will be displayed flashing 9 Adjust PIN digit 4 using S and T 10 Press OK to accept digit 4 If the PIN entered is incorrect the control will return to normal operation but if the PIN is correct then the user adjustmen...

Страница 10: ... operate the heater whatever the temperature When this mode is set only OFF is shown in the time display To set off mode press the O I button twice and OFF is displayed flashing in the time area Press OK to accept this mode To clear frost protection or off modes just press the O I button and normal control will resume 6 5 Constant comfort or savings temperature control timed mode only The control ...

Страница 11: ... drain only occurs when the control is disconnected from the 240V mains supply with the battery in situ Its purpose is to maintain the time and date settings correctly until the control is installed or during power cuts At all other times when the 240 V mains supply is connected there is no current drain to cause the battery life to deteriorate We recommend changing the Coin Battery when the bad b...

Страница 12: ...ation stored in non volatile EEPROM memory Connections 7 by 4 0 mm rising clamp screw terminal Live in Neutral in Live to load Neutral to load Earth no internal connection floor sensor signal floor sensor return Keypad buttons 6 silicon rubber S T OK MENU 24h O I LCD custom 16mm x 30mm 60 segment reflective no backlight see appendix DIL switch setting of operating modes by installer Switch 1 floor...

Отзывы: