6.3 Temporary temperature adjustment (timed mode only). 

 

The comfort or savings temperature that is currently operating can be temporarily adjusted using the 

S

 and 

T

 buttons. When the temperature has been 

manually changed in this way the HAND icon will be displayed. If the tamper lock has been set then this needs to be cleared before the adjustment can be 

made and reset after the adjustment. 

 

The control will revert to the permanent comfort or savings temperature at the start of the next timer period. When the temperature reverts the HAND icon 

will clear. 

 

Note: the temperature adjustment is from the current measured floor or room temperature (not the comfort or savings set temperature). This is so that the 

adjustment is relevant to the current environment being experienced not what it ought to be. For example if the room comfort temperature is set as 20°C 

but the room has only reached 15°C when the temporary adjustment is made then the user might not appreciate that the temperature is still to increase and 

would thus overheat the room if the adjustment was made from 20°C instead of 15°C. 

 

1.

 

Press 

S

 or 

T

 and the current measured room temperature will be displayed flashing with the THERMOMETER and HAND icons. If floor 

sensor only operation then the FLOOR THERMOMETER icon will be displayed. 

2.

 

Adjust the temperature up or down as required. 

3.

 

Press OK to complete the adjustment and return to normal operation with the current temperature displayed but with the revised temperature 

target. 

 

6.4 Off and frost protection modes. 

 

The control can be indefinitely set to either frost protection only mode or off mode. These modes are used for example for holiday periods, when the 

building is unoccupied or other times when the heating is not fully required. When operating with these modes the clock will keep running in the background 

and all of the settings and configuration will be preserved. 

 

In frost protection only mode the control only operates the heater to stop the floor or room temperature falling below 5°C. When this mode is set the 

FROST icon is displayed. If the control is in timed mode the TIME PERIOD icons are not displayed. 

 

To set frost protection mode press the O/I button once so that the FROST icon and 5°C is displayed flashing. Press OK to accept this mode. 

 

In off mode the control does not operate the heater whatever the temperature. When this mode is set only OFF is shown in the time display. 

 

To set off mode press the O/I button twice and OFF is displayed flashing in the time area. Press OK to accept this mode. 

 

To clear frost protection or off modes just press the O/I button and normal control will resume. 

 

6.5 Constant comfort or savings temperature control (timed mode only). 

 

The control can be indefinitely set to either comfort or savings temperature. This might be required for example for short holiday periods at home, periods 

when an occupant is convalescing, periods of extreme weather or periods where the building might be unoccupied for a few days. When the control is 

operating in permanent comfort or savings temperature mode the display will show the 24h and SUN or MOON icons but no TIMER PERIOD icons. 

 

To set constant comfort temperature press the 24h button once so that the 24h and SUN icons are displayed flashing. Press OK to accept this mode. 

 

To set constant savings temperature press the 24h button twice so that the 24h and MOON icons are displayed flashing. Press OK to accept this mode. 

 

To clear either constant comfort or savings temperature mode just press the 24h button and normal control will resume. 

 

It is still possible to ‘temporarily’ adjust the temperature during constant comfort or savings temperature mode and the temporary adjustment will reset when 

the period of constant comfort or savings temperature is cleared. 

 

7. Displays. 

 

7.1 Normal use display. 

 

In normal use the control displays either the room temperature (room and floor sensor/room sensor only modes) or the floor temperature (floor sensor only 

mode). Additionally one or more icons may show additional functions as follows: 

 

 

If the control is in timed mode then the current TIMER PERIOD icon (1 to 4) will also be displayed. 

 

If the control temperature has been manually overridden then the HAND icon will also be displayed. 

 

If the control has been tamper locked then the PADLOCK icon will be also displayed. 

 

If the control has been PIN protected then the PADLOCK icon will be displayed when the control is protected and will be clear when the PIN 

has been entered and the 4 minute access period is still running. 

 

If the control has been changed to constant comfort or savings temperature then the 24h icon will also be displayed but not the TIMER PERIOD 

icons. 

 

If the control has been set to permanent frost protection mode then the FROST icon is displayed. 

 

If the control has been set to permanent off mode then only OFF is shown in the time display. 

 

Whenever the heater relay is on the HEATER icon will be displayed. 

 

If the clock backup battery is running low then the BAD BATTERY icon will be displayed. 

 

 

 

 

 

 

Содержание Vysa-Therm 3000

Страница 1: ...ng to open the control When timed operation is chosen the control uses a real time clock and timer periods to change the temperature between the comfort temperature and the savings temperature When un timed operation is chosen the control is set to the required temperature using S and T and controls to this temperature until it is manually adjusted OWNERS MANUAL Vysa Therm 3000 Electrical and elec...

Страница 2: ...to meet your own requirements 5 1 Enter PIN security code PIN Enabled 5 2 Set the tamper lock PIN not enabled 5 3 Floor temperature display Room and floor sensor only 5 4 Set timer periods Timer operation only 5 4 1 Set timer periods 1 day mode 5 4 2 Set timer periods 5 2 day mode 5 4 3 Set timer periods 7 day mode 5 5 Set comfort temperature 5 6 Set savings temperature 5 7 Set minimum floor tempe...

Страница 3: ...d 2 savings temperature starts 12 00 Timer period 3 comfort temperature starts 12 00 Timer period 4 savings temperature starts 23 00 2 3 Temperatures Default sensor mode is floor sensor only control from DIL switches Default temperature display mode is C Frost temperature is fixed as 5 C this is the floor or air temperature Savings temperature floor sensor only mode 20 C floor temperature Savings ...

Страница 4: ...day mode the days are grouped into weekdays and weekends and one set of timer periods apply to all week days Monday Tuesday Wednesday Thursday and Friday whilst another set of timer periods apply to all weekend days Saturday and Sunday In 7 day mode each day has its own set of timer periods and each can be different All timer period configurations offer 4 timer periods per day 3 4 Maximum floor te...

Страница 5: ...der Engineer Settings To access Engineer Settings press and hold the OK button then press the MENU button also Then press the MENU button until the appropriate icons for the item to be changed are shown on the display the variable being changed will be shown flashing ready for adjustment If the user stops programming part way through a process then after 1 minute the control will automatically ret...

Страница 6: ...igit 1 using S and T 4 Press OK to accept digit 1 The second 0 will be displayed flashing 5 Adjust PIN digit 2 using S and T 6 Press OK to accept digit 2 The third 0 will be displayed flashing 7 Adjust PIN digit 3 using S and T 8 Press OK to accept digit 3 The fourth 0 will be displayed flashing 9 Adjust PIN digit 4 using S and T 10 Press OK to accept digit 4 and advance to next item in configurat...

Страница 7: ... to 24 00 Timer period 4 timer period 3 to 24 00 This range of times gives flexibility to programming in particular if timer period 2 and timer period 3 are set as the same time then effectively there is only one comfort period for that day beginning at timer period 1 and ending at timer period 4 5 4 1 Set timer periods 1 day mode In 1 day mode the day icons are not used when setting timer periods...

Страница 8: ...ntil Set and MOON and THERMOMETER icons are displayed If floor sensor only operation then the FLOOR THERMOMETER icon is displayed 2 Savings temperature will be flashing 3 Adjust temperature using S and T 4 Press OK to accept savings temperature and return to normal operation 5 7 Set minimum floor temperature floor sensor enabled only 1 Press MENU until Set and FLOOR THERMOMETER and Min icons are d...

Страница 9: ...ng 5 Adjust PIN digit 2 using S and T 6 Press OK to accept digit 2 The third 0 will be displayed flashing 7 Adjust PIN digit 3 using S and T 8 Press OK to accept digit 3 The fourth 0 will be displayed flashing 9 Adjust PIN digit 4 using S and T 10 Press OK to accept digit 4 If the PIN entered is incorrect the control will return to normal operation but if the PIN is correct then the user adjustmen...

Страница 10: ... operate the heater whatever the temperature When this mode is set only OFF is shown in the time display To set off mode press the O I button twice and OFF is displayed flashing in the time area Press OK to accept this mode To clear frost protection or off modes just press the O I button and normal control will resume 6 5 Constant comfort or savings temperature control timed mode only The control ...

Страница 11: ... drain only occurs when the control is disconnected from the 240V mains supply with the battery in situ Its purpose is to maintain the time and date settings correctly until the control is installed or during power cuts At all other times when the 240 V mains supply is connected there is no current drain to cause the battery life to deteriorate We recommend changing the Coin Battery when the bad b...

Страница 12: ...ation stored in non volatile EEPROM memory Connections 7 by 4 0 mm rising clamp screw terminal Live in Neutral in Live to load Neutral to load Earth no internal connection floor sensor signal floor sensor return Keypad buttons 6 silicon rubber S T OK MENU 24h O I LCD custom 16mm x 30mm 60 segment reflective no backlight see appendix DIL switch setting of operating modes by installer Switch 1 floor...

Отзывы: