Vysa-Therm™ 3000: 000807
Vysal Limited. Unit 3 Lovett Farm, Little Somerford, Wiltshire, SN15 5BP. Tel : 01666 822059 Fax: 01666 822422
Email: [email protected] Web: www.floor-heating.co.uk
5.1 Enter PIN (PIN enabled only).
1.
Press MENU to access settings menu. The PADLOCK icon and 0000 are displayed.
2.
The first 0 will be displayed flashing.
3.
Adjust PIN digit 1 using
S
and
T
.
4.
Press OK to accept digit 1. The second 0 will be displayed flashing.
5.
Adjust PIN digit 2 using
S
and
T
.
6.
Press OK to accept digit 2. The third 0 will be displayed flashing.
7.
Adjust PIN digit 3 using
S
and
T
.
8.
Press OK to accept digit 3. The fourth 0 will be displayed flashing.
9.
Adjust PIN digit 1 using
S
and
T
.
10.
Press OK to accept digit 4. If the PIN entered is incorrect the control will return to normal operation but if the PIN is correct then the settings
menu will be accessed and remain accessible for 4 minutes.
5.2 Set tamper lock on or off (PIN not enabled only).
1.
Press MENU until Set and PADLOCK icons are displayed.
2.
On or Off will be displayed flashing in the time area.
3.
Adjust lock state using
S
and
T
.
4.
Press OK to accept lock state and return to normal operation.
5.3 Floor temperature display (room + floor sensor mode only).
The temperature reading of the floor sensor can be displayed temporarily. (Whilst in Floor Air sensor mode)
1.
Press MENU until FLOOR TEMPERATURE icon and the floor sensor temperature reading are displayed.
2.
Press OK to return to normal operation.
5.4 Set timer periods (timed mode only).
Dependant on whether the control has been set as a 1 day, 5:2 day or a 7 day the timer periods are set differently. Timer periods are set with a resolution of
10 minutes, e.g. 00, 10, 20, 30, 40, 50 minutes.
The range of times for each timer period can be set as follows:
Timer period 1, 00:00 to 24:00
Timer period 2, timer period 1 to 24:00
Timer period 3, timer period 2 to 24:00
Timer period 4, timer period 3 to 24:00
This range of times gives flexibility to programming; in particular if timer period 2 and timer period 3 are set as the same time then effectively there is only one
comfort period for that day beginning at timer period 1 and ending at timer period 4.
5.4.1 Set timer periods, 1 day mode.
In 1 day mode the day icons are not used when setting timer periods.
1.
Press MENU until Set and TIME PERIOD 1 icons are displayed.
2.
Time period 1 set time will be displayed flashing.
3.
Adjust the set time using
S
and
T
.
4.
Press OK to accept the set time.
5.
TIME PERIOD 2 icon will be displayed and Time period 2 set time will be displayed flashing.
6.
Adjust the set time using
S
and
T
.
7.
Press OK to accept the set time.
8.
TIME PERIOD 3 icon will be displayed and Time period 3 set time will be displayed flashing.
9.
Adjust the set time using
S
and
T
.
10.
Press OK to accept the set time.
11.
TIME PERIOD 4 icon will be displayed and Time period 4 set time will be displayed flashing.
12.
Adjust the set time using
S
and
T
.
13.
Press OK to accept the set time and return to normal operation.
5.4.2 Set timer periods, 5:2 day mode.
Weekdays Mo/Tu/We/Th/Fr will be programmed first.
1.
Press MENU until Set, TIME PERIOD 1 and Mo/Tu/We/Th/Fr icons are displayed.
2.
Time period 1 set time will be displayed flashing.
3.
Adjust the set time using
S
and
T
.
4.
Press OK to accept the set time.
5.
TIME PERIOD 2 icon will be displayed and Time period 2 set time will be displayed flashing.
6.
Adjust the set time using
S
and
T
.
7.
Press OK to accept the set time.
8.
TIME PERIOD 3 icon will be displayed and Time period 3 set time will be displayed flashing.
9.
Adjust the set time using
S
and
T
.
10.
Press OK to accept the set time.
11.
TIME PERIOD 4 icon will be displayed and Time period 4 set time will be displayed flashing.
12.
Adjust the set time using
S
and
T
.
13.
Press OK to accept the set time and advance to Sa/Su day group programming.
Sa/Su day group is programmed just as Mo/Tu/We/Th/Fr was. After Sa/Su programming the control returns to normal operation.