background image

For additional product or technical information, visit  

www.vwr.com 

or contact your local sales office.

Manufactured for VWR international, LLC  

100 Matsonford Rd, Radnor, Pa 19087 

Version 1

Made in Poland

Austria

VWR international GmbH 

Graumanngasse 7 

1150 Vienna 

Tel.: +43 1 97 002 0 

email: [email protected]

Belgium 

VWR international BV 

Researchpark Haasrode 2020 

Geldenaaksebaan 464 

3001 Leuven 

Tel.: +32 016 385 011 

email: [email protected]

Canada

VWR international 

2360 argentia Road 

Mississauga, Ontario L5n 5Z7 

Tel.: +1 800 932 5000 

email:   Canada_Orders@

vwr.com

China

VWR (Shanghai) Co., Ltd 

Bld.no.1, no.3728 Jinke Rd, 

Pudong new district 

Shanghai, 201203- China 

Tel.: +400 821 8006 

email: [email protected]

Czech Republic

VWR international s. r. o. 

Veetee Business Park  

Pražská 442 

CZ - 281 67  Stríbrná Skalice 

Tel.: +420 321 570 321 

email: [email protected]

Denmark

VWR international a/S 

Tobaksvejen 21 

2860 Søborg 

Tel.: +45 43 86 87 88 

email: [email protected]

Finland

VWR international Oy 

Valimotie 17-19 

00380 Helsinki 

Tel.: +358 9 80 45 51 

email: [email protected]

France

VWR international S.a.S. 

immeuble estréo 

1-3 rue d’aurion 

93114 Rosny-sous-Bois cedex  

Tel.: 0 825 02 30 30* (national) 

Tel.: +33 (0) 1 45 14 85 00 

(international) 

email: [email protected] 

* 0,18 € TTC/ min + prix appel

Germany

VWR international GmbH 

Hilpertstrasse 20a 

d - 64295 darmstadt 

Freecall: 0800 702 00 07 

Tel.: +49 (0) 6151 3972 0 

(international) 

email: [email protected]

Hungary

VWR international Kft. 

Simon László u. 4. 

4034 debrecen 

Tel.: +36 (52) 521-130 

email: [email protected]

India

VWR Lab Products Private 

Limited 

no.139. Bda industrial Suburb,  

6th Main, Tumkur Road,  

Peenya Post,  

Bangalore, india – 560058 

Tel.: +91-80-28078400 

email: [email protected]

Ireland   

Northern Ireland

VWR international Ltd / 

VWR international (northern 

ireland) Ltd 

Orion Business Campus 

northwest Business Park 

Ballycoolin 

dublin 15 

Tel.: +353 01 88 22 222 

email [email protected]

Italy

VWR international S.r.l. 

Via San Giusto 85 

20153 Milano (Mi) 

Tel.: +39 02-3320311/02-487791 

email: [email protected]

Korea

avantor Performance Materials 

Korea Ltd 

2F aCe Gwanggyo Tower i 

daehak 4ro 17 

Yeongtong-gu Suwon 

Korea 16226 

Tel.: +82 31 645 7250 

email:   saleskorea@avantor-

sciences.com

Mexico

VWR international, S.de R.L. 

de C.V.  

Km. 14.5 Carretera 

Tlalnepantla-Cuautitlán 

Col. Lechería 

Tultitlán edo. de México 

CP 54940 

Tel.: +52 (55) 5005 0100 

email:   [email protected]

Middle East & Africa

VWR international FZ-LLC 

dSP Laboratory Complex 

125, Floor 01 

dubai, United arab emirates 

Tel.: +971 4 5573271 

[email protected]

The Netherlands

VWR international B.V. 

Postbus 8198 

1005 ad amsterdam 

Tel.: +31 020 4808 400 

email: [email protected]

Norway

VWR international aS 

Brynsalleen 4 

0667 Oslo 

Tel.: +47 22 90 00 00 

email: [email protected]

Poland

VWR international Sp. z o.o. 

Limbowa 5 

80-175 Gdańsk 

Tel.: +48 058 32 38 210  

email: [email protected]

Portugal

VWR international - Material 

de Laboratório, Lda 

Centro empresarial de 

alfragide 

Rua da indústria, nº 6 

2610-088 amadora 

Tel.: +351 21 3600 770 

email: [email protected]

Singapore

VWR Singapore Pte Ltd 

18 Gul drive 

Singapore 629468 

Tel: +65 6505 0760 

email: [email protected]

Spain

VWR international eurolab S.L. 

C/ Tecnología 5-17 

a-7 Llinars Park 

08450 - Llinars del Vallès 

Barcelona 

Tel.: +34 902 222 897 

email: [email protected]

Sweden

VWR international aB 

Fagerstagatan 18b 

163 94 Stockholm 

Tel.: +46 08 621 34 20 

email: [email protected]

Switzerland

VWR international GmbH 

Lerzenstrasse 16/18 

8953 dietikon 

Tel.: +41 044 745 13 13 

email: [email protected]

UK

VWR international Ltd 

Customer Service Centre 

Hunter Boulevard 

Magna Park 

Lutterworth 

Leicestershire 

Le17 4Xn 

Tel.: +44 (0) 800 22 33 44 

email: [email protected]

United States

VWR international, LLC 

100 Matsonford Road 

Building One Suite 200 

Radnor, Pa 19087 

Tel.: +1  800 932 5000 

email:   vwrcustomerService@

vwr.com

Содержание avantor

Страница 1: ...tandard Line Instruction Manual Pipettors VWR Standard Line VWR 8 channel Standard Line VWR 12 channel Standard Line This manual is available in additional languages at www vwr com PMS 647C CMYK 96 54...

Страница 2: ...s are designed for microplate filling The pipet tors enable precise and simultaneous delivery of 8 or 12 preset volumes of liquid These pipettors are available in four volume ranges 0 5 10 L 5 50 L 20...

Страница 3: ...ti channel manifold Contains a set of plungers and a set of flexible suspension shafts which func tion to reduce the force required to attach the tip Model Identification The volume range of the pipet...

Страница 4: ...Accuracy Precision Non filter Tips L Single channel Pipettors 2 Min 0 1 40 0 12 0 10 0 2 12 0 6 0 1 2 7 1 3 Max 2 1 5 0 7 10 Min 0 5 4 0 2 8 10 1 0 2 5 1 8 5 0 1 0 0 6 Max 10 0 0 5 0 4 20 Min 2 3 0 1...

Страница 5: ...o not attach the tips with a rocking movement as this may damage the shaft or plunger Observe this rule particularly with single channel pipettors of low volume range Never draw liquids directly into...

Страница 6: ...In 2 and 10 L pipettors place the cap that can be purchased separately on the bottom of the pipettor shaft and slide the cap upwards to the bottom of the tip ejector M L 10000 L L 10mm 5000 L L 6mm M...

Страница 7: ...ded to pre rinse the tip several times prior to use Do not pipette liquids with temperatures above 70 C NOTE When pipetting acids or corrosive solutions which emit vapors it is recommended to disassem...

Страница 8: ...ISO 8655 guidelines for the maximum nominal liquid volume drawn by the pipettor and for 10 of the maximum or minimum liquid volume according to the values given Section 5 The pipettors are designed t...

Страница 9: ...rm 10 aspirations and calculate the average value in mg Calculate the volume in L by multiplying the value in mg by the conversion factor Z L mg If the average aspirated volume exceeds the permissible...

Страница 10: ...accuracy should not alter if the pipet ting processes including autoclaving are carried out as described in this manual If a change in accuracy occurs it is recommended to Check the calibration of the...

Страница 11: ...ling elements are not sufficiently lubricated e g after repeated autoclaving procedures Incorrect aspiration Liquid with properties other than water den sity viscosity Calibrate the pipettor using the...

Страница 12: ...tional product information and special offers Contact us For information or technical assistance contact your local VWR representative or visit ww vwr com 14 Warranty VWR warrants that this product wi...

Страница 13: ...s Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 02 487791 Email inf...

Отзывы: