background image

22 – VWR STandaRd Line PiPeTTORS 

instruction Manual – 23

Item

Description

Model (μL)

Cat. No. Qty/Pk

D

Tip ejector

2, 10

SP19051

1

20, 100

SP19052

1

200

SP19054

1

1,000

SP19056

1

5,000

SP19452

1

10,000

SP19453

1

F

Shaft nut

2 - 1,000

SP29449

1

G

Plunger assembly

2

SP19381

1

10

SP19382

1

20

SP19383

1

100

SP19384

1

200

SP19385

1

1,000

SP19386

1

5,000

SP19388

1

10,000

SP19389

1

I,  

J*

O-ring (and seal)

2

SP19101

10

10

SP19102

10

20

SP19103

10

100

SP19104

10

200

SP19105

10

1,000

SP19106

10

5,000

SP19108

5

10,000

SP19109

5

K

Calibration key

all

SP9479

1

L

Shaft filter

5,000, 10,000 SP19476

10

M

Tip ejector cap

2, 10

SP19378

3

5,000

SP19466

3

10,000

SP19467

3

S

Shelf clip

all

SP19483

1

*Seal (

J

) used only in models 2, 5,000 and 10,000 μL

 13.  Technical  service

Web Resources

Visit the VWR website at 

www.vwr.com

 for:

 

Complete technical service contact information

 

access to the VWR Online Catalogue, and information 

about accessories and related products

 

additional product information and special offers

Contact us 

For information or technical assistance contact your 

local VWR representative or visit 

ww.vwr.com

 14.  Warranty

VWR

 warrants that this product will be free from defects 

in material and workmanship for a period of three (3) 

years from date of delivery. if a defect is present, VWR 

will, at its option and cost, repair, replace, or refund the 

purchase price of this product to the customer, provided 

it is returned during the warranty period. This warranty 

does not apply if the product has been damaged by 

accident, abuse, misuse, or misapplication, or from 

ordinary wear and tear. if the required maintenance and 

inspection services are not performed according to the 

manuals and any local regulations, such warranty turns 

invalid, except to the extent, the defect of the product is 

not due to such non-performance.

items being returned must be insured by the cus-

tomer against possible damage or loss. This warranty 

shall be limited to the aforementioned remedies. iT iS 

eXPReSSLY aGReed THaT THiS WaRRanTY WiLL Be 

in LieU OF aLL WaRRanTieS OF FiTneSS and in LieU 

OF THe WaRRanTY OF MeRCHanTaBiLiTY.

Содержание avantor

Страница 1: ...tandard Line Instruction Manual Pipettors VWR Standard Line VWR 8 channel Standard Line VWR 12 channel Standard Line This manual is available in additional languages at www vwr com PMS 647C CMYK 96 54...

Страница 2: ...s are designed for microplate filling The pipet tors enable precise and simultaneous delivery of 8 or 12 preset volumes of liquid These pipettors are available in four volume ranges 0 5 10 L 5 50 L 20...

Страница 3: ...ti channel manifold Contains a set of plungers and a set of flexible suspension shafts which func tion to reduce the force required to attach the tip Model Identification The volume range of the pipet...

Страница 4: ...Accuracy Precision Non filter Tips L Single channel Pipettors 2 Min 0 1 40 0 12 0 10 0 2 12 0 6 0 1 2 7 1 3 Max 2 1 5 0 7 10 Min 0 5 4 0 2 8 10 1 0 2 5 1 8 5 0 1 0 0 6 Max 10 0 0 5 0 4 20 Min 2 3 0 1...

Страница 5: ...o not attach the tips with a rocking movement as this may damage the shaft or plunger Observe this rule particularly with single channel pipettors of low volume range Never draw liquids directly into...

Страница 6: ...In 2 and 10 L pipettors place the cap that can be purchased separately on the bottom of the pipettor shaft and slide the cap upwards to the bottom of the tip ejector M L 10000 L L 10mm 5000 L L 6mm M...

Страница 7: ...ded to pre rinse the tip several times prior to use Do not pipette liquids with temperatures above 70 C NOTE When pipetting acids or corrosive solutions which emit vapors it is recommended to disassem...

Страница 8: ...ISO 8655 guidelines for the maximum nominal liquid volume drawn by the pipettor and for 10 of the maximum or minimum liquid volume according to the values given Section 5 The pipettors are designed t...

Страница 9: ...rm 10 aspirations and calculate the average value in mg Calculate the volume in L by multiplying the value in mg by the conversion factor Z L mg If the average aspirated volume exceeds the permissible...

Страница 10: ...accuracy should not alter if the pipet ting processes including autoclaving are carried out as described in this manual If a change in accuracy occurs it is recommended to Check the calibration of the...

Страница 11: ...ling elements are not sufficiently lubricated e g after repeated autoclaving procedures Incorrect aspiration Liquid with properties other than water den sity viscosity Calibrate the pipettor using the...

Страница 12: ...tional product information and special offers Contact us For information or technical assistance contact your local VWR representative or visit ww vwr com 14 Warranty VWR warrants that this product wi...

Страница 13: ...s Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 02 487791 Email inf...

Отзывы: