4 – VWR STandaRd Line PiPeTTORS 

instruction Manual – 5

 2.  Packing

The pipettors are delivered with the following:

Description

Qty/Pk

instruction manual

1

Quality Control certificate

1

Calibration key

1

Shelf clip

1

Lubricant (for single-channel pipettor)

1

ejector cap (for pipettor model 10,000 µL)

1

Filters

The 5,000 and 10,000 μL pipettors include a replaceable 

filter, fitted at the bottom of the shaft which prevents 

aspirated liquid from entering the shaft and contami-

nating the inner surface and plunger. Use of the filter is 

particularly important when aspirating and dispensing 

large volumes of liquid. The filter should be replaced if it 

becomes wet.

 3.  Pipettor  Design

Single- and Multi-channel Pipettors

A1

A2

N

B

C

D

R

A

F

 A.  Pipetting  pushbutton: 

Consists of 2 parts:  

the pushbutton (

A1

) and the knob (

A2

). 

 B.  Volume adjustment knob: 

Used to set the volume.

 C.  Shaft: 

Manufactured using high quality plastic, 

ensuring high chemical and mechanical strength.

 D.  Tip  ejector: 

For multi-channel pipettors, the tips are 

ejected sequentially, reducing the required force.

 F.  Shaft nut
 N.  Ejector  pushbutton
 R.  Multi-channel  manifold: 

Contains a set of plungers 

and a set of flexible-suspension shafts, which func-

tion to reduce the force required to attach the tip.

Model Identification

The volume range of the pipettor is shown on the 

pushbutton and on the tip ejector bar in multi-channel 

pipettors.

 4.  Safety  Recommendations 

Long-term use of the pipettor relies on correct method 

of use. Please read and follow the instructions for use 

carefully. 
Symbols used: 

danger, risk of injury.

NOTE

Risk of damage to the pipettor or errors  

in pipetting.

NOTE:

 

The pipettor is designed for the transfer of liquids only 

using the tip. do not aspirate liquids without the tip 

attached. The aspirated liquid should not enter the 

pipettor, as it may cause damage.

 

Single-use tips reduce the risk of contamination of 

samples.

 

Keep the pipettor clean, avoiding the use of abrasive 

or corrosive cleaning agents (e.g., acetone). 

 

Keep the pipettor upright when there is liquid in the 

tip.

 

Only using the pipettor in accordance with the manu-

facturer’s instructions ensures the correct pipettor 

parameters are maintained.

 

after replacing the plunger or the shaft, the pipettor 

should be calibrated.

 

in the case of incorrect operation, the device should 

be cleaned in accordance with the instruction Manual 

or transferred to a service point.

Содержание avantor

Страница 1: ...tandard Line Instruction Manual Pipettors VWR Standard Line VWR 8 channel Standard Line VWR 12 channel Standard Line This manual is available in additional languages at www vwr com PMS 647C CMYK 96 54...

Страница 2: ...s are designed for microplate filling The pipet tors enable precise and simultaneous delivery of 8 or 12 preset volumes of liquid These pipettors are available in four volume ranges 0 5 10 L 5 50 L 20...

Страница 3: ...ti channel manifold Contains a set of plungers and a set of flexible suspension shafts which func tion to reduce the force required to attach the tip Model Identification The volume range of the pipet...

Страница 4: ...Accuracy Precision Non filter Tips L Single channel Pipettors 2 Min 0 1 40 0 12 0 10 0 2 12 0 6 0 1 2 7 1 3 Max 2 1 5 0 7 10 Min 0 5 4 0 2 8 10 1 0 2 5 1 8 5 0 1 0 0 6 Max 10 0 0 5 0 4 20 Min 2 3 0 1...

Страница 5: ...o not attach the tips with a rocking movement as this may damage the shaft or plunger Observe this rule particularly with single channel pipettors of low volume range Never draw liquids directly into...

Страница 6: ...In 2 and 10 L pipettors place the cap that can be purchased separately on the bottom of the pipettor shaft and slide the cap upwards to the bottom of the tip ejector M L 10000 L L 10mm 5000 L L 6mm M...

Страница 7: ...ded to pre rinse the tip several times prior to use Do not pipette liquids with temperatures above 70 C NOTE When pipetting acids or corrosive solutions which emit vapors it is recommended to disassem...

Страница 8: ...ISO 8655 guidelines for the maximum nominal liquid volume drawn by the pipettor and for 10 of the maximum or minimum liquid volume according to the values given Section 5 The pipettors are designed t...

Страница 9: ...rm 10 aspirations and calculate the average value in mg Calculate the volume in L by multiplying the value in mg by the conversion factor Z L mg If the average aspirated volume exceeds the permissible...

Страница 10: ...accuracy should not alter if the pipet ting processes including autoclaving are carried out as described in this manual If a change in accuracy occurs it is recommended to Check the calibration of the...

Страница 11: ...ling elements are not sufficiently lubricated e g after repeated autoclaving procedures Incorrect aspiration Liquid with properties other than water den sity viscosity Calibrate the pipettor using the...

Страница 12: ...tional product information and special offers Contact us For information or technical assistance contact your local VWR representative or visit ww vwr com 14 Warranty VWR warrants that this product wi...

Страница 13: ...s Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 02 487791 Email inf...

Отзывы: