5
-
3. NFPA Standard # 96
Vapor Removal from Cooking Equipment
, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
BURNERS, RADIANTS, AND TOP GRATES
The top grates are shipped flat (top-side down) from the factory. For broiling, the top grates can be left
in the flat position or reversed so they slope forward for grease run-off. Remove the cast iron grates
and radiants. Inspect and remove the shipping restraints used during shipping to hold the burners.
Reassemble the radiants and top grates. See Fig. 1.
Burners
Radiants
Top Grates
Fig. 1