ERA & EBD SERIES ELECTRIC FRYERS - TROUBLESHOOTING
TROUBLESHOOTING
ALL MODELS
SYMPTOMS
POSSIBLE CAUSES
Fryer does not heat, but voltage IS present
between J2 and J9.
1.
Tilt switch covered with debris or malfunction (heating
elements are lowered).
2.
High limit thermostat open.
3.
Contactor(s) malfunction.
4.
Cooking control malfunction (no output from terminal J5).
5.
R1 heat relay malfunction.
6.
Interconnecting wiring malfunction.
Fryer does not heat, voltage NOT present
between J2 and J9.
1.
Check main power to unit.
2.
Internal circuit breaker OFF (24kW, 208-240V units only).
3.
Power switch off or malfunction.
4.
Transformer inoperative.
5.
R2 power relay malfunction.
6.
Drain valve switch open or switch malfunction.
7.
Interconnecting wiring malfunction.
Excessive time to melt solid shortening
(more than 45 minutes).
1.
Melt cycle timing incorrect.
2.
Incorrect supply voltage.
3.
Temperature probe malfunction.
4.
Cooking control malfunction.
Excessive or low heat.
1.
Incorrect supply voltage.
2.
Temperature probe malfunction.
3.
Contactor(s) malfunction.
4.
R1 heat relay malfunction.
5.
Heating element malfunction (low heat).
6.
Cooking control malfunction.
Intermittent problems.
1.
High ambient temperatures.
2.
Wiring connections loose.
FRYMATE (DUMP STATION)
WITH OPTIONAL HEATER
SYMPTOM
POSSIBLE CAUSES
No heat.
1.
Unplugged.
2.
Power switch off or inoperative.
3.
Main circuit breaker off or open.
4.
Malfunctioning heater assembly.
F25385 (May 2010)
Page 31 of 32
Содержание 136730
Страница 25: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F25385 May 2010 Page 25 of 32 ...
Страница 27: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F25385 May 2010 Page 27 of 32 ...
Страница 29: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F25385 May 2010 Page 29 of 32 ...
Страница 30: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION Frymate Dump Station F25385 May 2010 Page 30 of 32 ...