ERA & EBD SERIES ELECTRIC FRYERS - ELECTRICAL OPERATION
KLEENSCREEN FILTER CONTROLS
Fill Solenoid Valve . . . . . . . . . . . .
When energized by filter switch, the solenoid valve opens to allow the flow of
shortening thru filtering system.
Pump Motor . . . . . . . . . . . . . . . . .
Operates pump to circulate shortening through filtering system.
Start Switch . . . . . . . . . . . . . . . . . .
Supplies start heating function to the temperature control at the beginning of
a cooking cycle or after the vat has been filled from the filter process.
Filter Switch . . . . . . . . . . . . . . . . .
Energizes pump motor to filter the shortening when switch is closed (valve
handle extended). Filter power switch must be turned on.
Discard Valve Switch . . . . . . . . . .
A magnetic reed switch mounted on the mechanical discard valve that
closes when discard valve handle is extended to discard the shortening.
Prevents R4 solenoid relay N.C. contacts from suppling power to the fill
solenoid valve when filter key is pressed.
R3 Filter Relay . . . . . . . . . . . . . . . .
Supplies power to pump motor and solenoid.
R4 Solenoid Relay . . . . . . . . . . . .
Removes power to solenoid if discard valve switch is operated.
F25385 (May 2010)
Page 18 of 32
Содержание 136730
Страница 25: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F25385 May 2010 Page 25 of 32 ...
Страница 27: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F25385 May 2010 Page 27 of 32 ...
Страница 29: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F25385 May 2010 Page 29 of 32 ...
Страница 30: ...ERA EBD SERIES ELECTRIC FRYERS ELECTRICAL OPERATION Frymate Dump Station F25385 May 2010 Page 30 of 32 ...