ECU converter PBS Version: 1.3
Page 33/43
2.7
JR PROPO
The JR telemetry data system is only unidirectional, that means the sensor data is transmitted
from the receiver. It will not transmit data from the transmitter to the sensor. A parameterization
of the PBS ECU is not possible with this system.
The displays are described below using the example of an XG8.
JR Display
(Ex. XG8)
PBS
F-PACK A
ECU- Status as numerical current value (s. section 2.7.1)
F-PACK W
THROTTLE in %
F-PACK V
BATT or PUMP (s. section 2.7.2.2)
F-PACK C
FUEL (remaining fuel) in ml
TEMP.
EGT
RPM
RPM
In order to display the rotation speed correctly, the parameters for RPM must be set to: GEAR
RATIO , PROPELLER and MAGNET POLE to INH.
The parameter type (MAGNETIC , OPTICAL or MOTOR) does not matter.
The
ECU
converter
transmits
the
consumed FUEL (950ml) – but on the
radio the remaining fuel is displayed.
This means that the actual tank size must
be parameterized in ml in the settings in the
radio, here in the example the main tank
has 3000 ml volume, which is set as
capacity 3000mAh.
The tank size in the ECU should be greater
than or equal to the actual tank size (see
section 2.0.2.2).