ECU converter PBS Version: 1.3
Page 18/43
2.3.4.1
Alarms
Settings
Value range
Step size
Signal tone
100 . . . 2500 ml
10 ml
U
5.0 . . . 12.0 V
0.1 V
P
400 . . . 995
°C
5 °C
H
20.0 . . . 99.9
x 1000rpm
100 rpm
T
-10 / -1 / OFF
E
Upon delivery, the warning thresholds are set as shown in the picture.
F-RES
The alarm Fuel Reserve is signaled if the fueltank size is exceeded less fuel consumption set
at F - RES.
The alarm stops as soon as a status message is transmitted, i.e.: LOCK, COOL or ERROR.
In addition, the alarm can also be acknowledged by sending a throttle value below 10% for
a moment.
F-RES = OFF -> Alarm is disabled
BATT
The alarm BATT is signaled if the turbine battery voltage falls below the value set at BATT.
BATT = 5.0V -> should never occur , alarm is thus disabled
EGT
The alarm EGT is signaled if the temperature exceeds the value set at EGT.
EGT = 995°C -> should never occur , alarm is thus disabled
RPM
The alarm RPM is signaled if the rotation speed falls below the minimum rotation speed.
Speed monitoring is started when the speed exceeds the minimum speed and ends
at PUMP = 0,0V
RPM = OFF -> Alarm is disabled
ERROR = "turbine flameout"
"Error -10" are
all other errors
not listed in the table
which can lead to a shutdown of the turbine or not
even allow it to start.
If an alarm ERROR = -10 is programmed in the
transmitter a "turbine flameout " can safely be
signaled.
PBS
Turbine Status
ERROR
STOP
0
Th : I d l e
0
Th : -Re l
0
TEST
0
F IRE
0
START
0
I DLE
0
COOL
0
LOCK
-
1
Error
- 10