3 -
Connection Plan:
Note:
For safety reasons, the unit does not operate with LiFePO4 batteries, unless the
temperature sensor
had been connected! The sensor must be screwed-down to the negative pole of the battery.
Table 1: Recommended Cross-sections and Lengths for Charging Cables between Unit and Main Battery
I
:
Cable Cross-sections
Pb 1215
Pb 1220
Pb 1225
Pb 1230
2.5 mm
2
2x 0.6 ... 1.7 m
2x 0.5 ... 1.3 m
--
--
4 mm
2
2x 1.0 ... 2.7 m
2x 0.8 ... 2.0 m
2x 0.6 ... 1.6 m
2x 0.5 ... 1.3 m
6 mm
2
2x 1.5 ... 4.0 m
2x 1.1 ... 3.0 m
2x 0.9 ... 2.4 m
2x 0.8 ... 2.0 m
10 mm
2
2x 2.5 ... 6.7 m
2x 1.9 ... 5.0 m
2x 1.5 ... 4.0 m
2x 1.3 ... 3.3 m
Fuse 1
≥ 25 A
≥ 25 A
≥ 40 A
≥ 40 A
Safety Instruction: Connection is only allowed to a shock-proof socket, which has been installed
according to the valid technical regulations, protected with max. 16 A (if required
mobile/stationary with a fault current breaker (FI) with a nominal residual current of 30 mA).