Unit Settings: 

 

How to Set the Type (Design, Technology) of Main Battery "I": 

4 Charging programs

 for the different battery types are stored in the unit. They can be 

selected by means of the 

2 micro slide switches

 at the unit front:  

The 

control levers

 of the slide switches are shown in 

white

If not being specified divergently by the battery manufacturer, the suitable charging program for the 
supply battery 

 

Board 

I

 can be determined by means of the following description and the technical data (voltage rates 

U1 and U2). 

The possible parallel/floating operation with 12 V consumer loads being connected to the 
main battery "

I

" is also automatically considered by all charging programs. 

TS 

= Temperature Sensor 825 (effect with/without connection of the temperature sensor) 

 

Lead 

Batteries (Acid, Gel, AGM)

Three (3) charging programs, charging voltage rates and temperature equalization for batteries in lead 
technology:

 

 

1

 

"Lead Acid/AGM  1  14.4 V"

 

Switch Position 

 

 

  U1=14.40 V  U2=13.50 V  U3=13.20 V 
 

  2-5 h 

  24 h 

Continuous 

Universal charging program IU1oU2oU3 

 

for acid-lead-acid batteries acc. to DIN 57 510 / 

 

VDE 0510 for charging and trickle charging of

 

supply (board) batteries.

 

 

Ensures short charging times, high charging factor and 
acid mixing for open standard batteries and closed, 
SLA, low-maintenance, maintenance-free "non-solid 
electrolyte", "lead-acid", drive, lighting, solar and 
heavy-duty batteries. Also suitable for recently 
developed batteries (low-antimonous, with silver-
alloy, calcium or similar) and batteries with low (L) and 
very low (VL) water consumption. 
Adapted to closed, gas-tight 

AGM 

(absorbed glass mat) / lead-fleece batteries 

VRLA 

with indication of the charging voltage 

"

14.4 V

". 

 
 

2

 

"Gel"

 

Switch Position 

 

 

  U1=14.40 V  U2=13.80 V  U3=13.50 V 
 

6-12 h 

48 h 

Continuous 

Charging program IU1oU2oU3, adapted

 

 to closed, gas-tight 

Gel/dryfit

 

 

batteries 

VRLA 

with determined electrolyte, which are 

generally requiring longer dwell times U1 to achieve 
particularly high capacity storage and to avoid deep 
discharge (becoming "deaf") of the battery, such as 
EXIDE, Sonnenschein, "dryfit", Varta, Bosch, Banner, 
Mobil Technology etc. If not being specified 
divergently by the battery manufacturer, also 
recommended for batteries in round cell technology, 
such as EXIDE MAXXIMA (DC). 

 

 

Содержание Pb 1215 SMT 2B

Страница 1: ...oads such as alarm systems WLAN etc as well as the vehicle s starter battery see page 5 2 Charging Port II Separate auxiliary charging port 12 V 2 A 3 A for support charging and trickle charging of th...

Страница 2: ...the charger will reduce its charging capacity Solid and vibration reducing installation by means of the rubber feet Never remove these rubber feet Battery Connection and Battery Settings for Start up...

Страница 3: ...15 Pb 1220 Pb 1225 Pb 1230 2 5 mm 2 2x 0 6 1 7 m 2x 0 5 1 3 m 4 mm 2 2x 1 0 2 7 m 2x 0 8 2 0 m 2x 0 6 1 6 m 2x 0 5 1 3 m 6 mm 2 2x 1 5 4 0 m 2x 1 1 3 0 m 2x 0 9 2 4 m 2x 0 8 2 0 m 10 mm 2 2x 2 5 6 7 m...

Страница 4: ...e weak battery Sensitive consumers are protected by a voltage limitation in case of very low outside temperatures In case of summery temperatures the charging voltage is reduced to minimize the load g...

Страница 5: ...the internal monitoring functions of the equipment continue working The lighting intensity of the LED Current will be reduced or increased depending on the supplied current intensity It will turn off...

Страница 6: ...harging program IU1oU2oU3 for acid lead acid batteries acc to DIN 57 510 VDE 0510 for charging and trickle charging of supply board batteries Ensures short charging times high charging factor and acid...

Страница 7: ...battery without BMS Battery Management System and without equalization charging of the cells balancing as well as safety circuit is not admissible The battery temperature sensor must be installed at t...

Страница 8: ...d turns off shortly approx every 1 5 sec only with charging program LiFePO4 Li battery protection battery temperature below 0 C the charging current might be reduced for protection of the Li battery i...

Страница 9: ...ull charge point of the battery for automatic switching to U2 In case of slightly discharged batteries the duration of phase U1 will be kept short for relief of the battery and low maintenance expendi...

Страница 10: ...ith a fault current breaker FI with a nominal residual current of 30 mA 3 Connection in consideration of the indicated cable cross sections at the charging ports 4 Fuses of the indicated capacity are...

Страница 11: ...5 0 A Reverse Current from Battery Power Failure 0 5 mA 0 5 mA 0 5 mA 0 5 mA Reset Voltage 30 sec depending on Battery Type 12 75 V 13 25 V 12 75 V 13 25 V 12 75 V 13 25 V 12 75 V 13 25 V Limit of Cha...

Страница 12: ...s Declaration of Conformity In accordance with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022...

Отзывы: