11 -
Overvoltage Limitation:
Charging voltage limitation to max. 15.0 V during all charging modes to protect sensitive consumers.
Overload / Overheating Protection Charger:
The charger is equipped with a double electronic protection against overload and protects itself against adverse
installation conditions (e. g. insufficient ventilation, excessive ambient temperatures) by gradual reduction of the
charging capacity.
Technical Data:
Pb 1215
Pb 1220
Pb 1225
Pb 1230
SMT 2B
SMT 2B
SMT 2B
SMT 2B
Supply Voltage (Mains Frequency 45 - 65 Hz):
110 V - 230 V
(110 V-) 230 V
(110 V-) 230 V
(110 V-) 230 V
Voltage Range Mains Function, all Types:
85 V - 270 V, short-time 305 V (5 sec.)
Mains Voltage Range for Full Charging Capacity:
95 V - 270 V
180 V - 270 V
180 V - 270 V
180 V - 270 V
Mains Power Consumption max.:
240 W
330 W
400 W
490 W
Mains Power Consumption at Readiness for Charging:
1.9 W
1.9 W
2.1 W
2.1 W
Active Sinusoidal Power Factor Correction (CosPhi = 1):
Yes
Yes
Yes
Yes
Approx. Charging Current at 110 V Supply Voltage:
15 A
18 A
18 A
18 A
Main Charging Port Battery
I
:
Nominal Battery Voltage Lead/LiFePO4 Battery:
12 V/12 V-13.3 V 12 V/12 V-13.3V 12 V/12 V-13.3 V 12 V/12 V-13.3 V
Selectable Charging Programs Lead-Gel/AGM/Acid, LiFePO4:
4
4
4
4
Battery Capacity (recommended):
60 Ah-110 Ah
80 Ah-145 Ah
100 Ah-180 Ah
120 Ah-230 Ah
Battery Capacity (acc. to case of application, such as also LiFePO4) 38 Ah-170 Ah
50 Ah-230 Ah
60 Ah-290 Ah
75 Ah-350 Ah
Charging Current Main Charging, Phase
I
, 8 V to U1; 0-15.5 h:
15 A
20 A
25 A
30 A
Charging/Floating/Load Current, controlled, Phase U1-U2-U3:
0 A-15 A
0 A-20 A
0 A-25 A
0 A-30 A
Minimum Battery Voltage for Charging Start:
0 V
0 V
0 V
0 V
Preliminary Charging Current (Deeply Discharged Batt. 0 V-8 V): 7.5 A
10.0 A
12.5 A
15.0 A
Reverse Current from Battery (Power Failure):
<0.5 mA
<0.5 mA
<0.5 mA
<0.5 mA
Reset Voltage (30 sec.), depending on Battery Type:
12.75 V/13.25 V
12.75 V/13.25 V
12.75 V/13.25 V
12.75 V/13.25 V
Limit of Charging Voltage (Protection of Connected Consumers): 15.0 V
15.0 V
15.0 V
15.0 V
External Overvoltage Disconnection (20 sec.):
15.5 V
15.5 V
15.5 V
15.5 V
Ripple Factor Voltage:
< 30 mV rms
< 30 mV rms
< 30 mV rms
< 30 mV rms
Charging Timer:
4-fold
4-fold
4-fold
4-fold
Safety Protect. ag. Reverse Batt./Short-circuit/Back Discharge:
Yes
Yes
Yes
Yes
Safety Timer per Charging Phase I/U1/U2:
Yes
Yes
Yes
Yes
Lead Battery Regeneration at extended down-time 2x week: 1 h: Yes
Yes
Yes
Yes
LiFePO4 Auto Wake Up at extend. down-time, every 10 days 0.5 h: Yes
Yes
Yes
Yes
or Li Storage, LiFePO4 Standstill Trickle Charge (Seasonal):
Yes
Yes
Yes
Yes
Input for Battery Temperature Sensor:
Yes
Yes
Yes
Yes
Power Pack Operation (e. g. Supply During Battery Replacement): Yes
Yes
Yes
Yes
2. Auxiliary Port Vehicle's Starter Battery
II
(Signalling Port Mains)
:
Nominal Battery Voltage (Lead):
12 V
12 V
12 V
12 V
Charging Current or Rating as Signalling Port:
0 A-2 A
0 A-2 A
0 A-3 A
0 A-3 A
Safety Protect. ag. Reverse Batt./Short-circuit/Back Discharge:
Yes
Yes
Yes
Yes
Connection for Remote Control Automatic Charger:
Yes
Yes
Yes
Yes
Fitting Position of Unit:
any
any
any
any
Temperature Range:
-20/+45 °C
-20/+45 °C
-20/+45 °C
-20/+45 °C
Speed-controlled, temperature-controlled Fan:
Yes
Yes
Yes
Yes
Gradual Reduction of Charging Capacity at Overtemperature:
Yes
Yes
Yes
Yes
Safety Disconnection in Case of Overheating:
Yes
Yes
Yes
Yes
Noise-reduction of Fan, Night Operation (Silent Run):
Yes
Yes
Yes
Yes
Protection Class/System of Protection:
I / IP21
I / IP21
I / IP21
I / IP21
Dimensions, incl. Mounting Flanges (mm):
215 x 160 x 72
215 x 160 x 72
215 x 160 x 72
215 x 160 x 72
Weight:
1250 g
1280 g
1300 g
1350 g
Ambient Conditions, Humidity of Air:
max. 95 % RH, no condensation
Safety Regulations:
EN 60335-2-29