background image

 - 

11 -

 

 

Overvoltage Limitation:  

Charging voltage limitation to max. 15.0 V during all charging modes to protect sensitive consumers. 

 

Overload / Overheating Protection Charger: 

The charger is equipped with a double electronic protection against overload and protects itself against adverse 
installation conditions (e. g. insufficient ventilation, excessive ambient temperatures) by gradual reduction of the 
charging capacity. 

 
 
 
 

Technical Data: 

Pb 1215 

Pb 1220 

Pb 1225 

Pb 1230 

 

 

SMT 2B 

SMT 2B 

SMT 2B 

SMT 2B 

 

Supply Voltage (Mains Frequency 45 - 65 Hz): 

110 V - 230 V   

(110 V-) 230 V 

(110 V-) 230 V 

(110 V-) 230 V 

Voltage Range Mains Function, all Types: 

                               85 V - 270 V,   short-time 305 V (5 sec.) 

Mains Voltage Range for Full Charging Capacity: 

95 V - 270 V 

180 V - 270 V 

180 V - 270 V 

180 V - 270 V 

Mains Power Consumption max.: 

240 W  

330 W 

400 W 

490 W 

Mains Power Consumption at Readiness for Charging: 

1.9 W  

1.9 W 

2.1 W 

2.1 W

  

Active Sinusoidal Power Factor Correction (CosPhi = 1): 

  Yes 

Yes 

Yes 

Yes 

Approx. Charging Current at 110 V Supply Voltage: 

15 A  

18 A 

18 A 

18 A 

 

Main Charging Port Battery 

I

:

 

Nominal Battery Voltage Lead/LiFePO4 Battery: 

12 V/12 V-13.3 V  12 V/12 V-13.3V  12 V/12 V-13.3 V  12 V/12 V-13.3 V 

Selectable Charging Programs Lead-Gel/AGM/Acid, LiFePO4:  

  4 

  4 

  4 

  4 

Battery Capacity (recommended): 

60 Ah-110 Ah 

80 Ah-145 Ah 

100 Ah-180 Ah 

120  Ah-230 Ah 

Battery Capacity (acc. to case of application, such as also LiFePO4)  38 Ah-170 Ah 

50 Ah-230 Ah 

  60 Ah-290 Ah 

   75 Ah-350 Ah 

Charging Current Main Charging, Phase 

I

, 8 V to U1; 0-15.5 h:  

15 A  

20 A 

25 A 

30 A 

Charging/Floating/Load Current, controlled, Phase U1-U2-U3:  

0 A-15 A 

0 A-20 A 

0 A-25 A  

0 A-30 A 

Minimum Battery Voltage for Charging Start: 

0 V  

0 V 

0 V 

0 V 

Preliminary Charging Current (Deeply Discharged Batt. 0 V-8 V):  7.5 A  

10.0 A 

12.5 A 

15.0 A 

Reverse Current from Battery (Power Failure): 

<0.5 mA  

<0.5 mA  

<0.5 mA  

<0.5 mA  

Reset Voltage (30 sec.), depending on Battery Type:  

12.75 V/13.25 V 

12.75 V/13.25 V 

12.75 V/13.25 V 

12.75 V/13.25 V 

Limit of Charging Voltage (Protection of Connected Consumers):  15.0 V  

15.0 V 

15.0 V 

15.0 V 

External Overvoltage Disconnection (20 sec.):  

15.5 V  

15.5 V 

15.5 V 

15.5 V 

Ripple Factor Voltage: 

< 30 mV rms

 

< 30 mV rms 

< 30 mV rms 

< 30 mV rms 

Charging Timer:   

4-fold 

4-fold 

4-fold 

4-fold 

Safety Protect. ag. Reverse Batt./Short-circuit/Back Discharge: 

  Yes 

Yes 

Yes 

Yes 

Safety Timer per Charging Phase I/U1/U2: 

  Yes 

Yes 

Yes 

Yes 

Lead Battery Regeneration at extended down-time 2x week: 1 h:    Yes 

Yes 

Yes 

Yes 

LiFePO4 Auto Wake Up at extend. down-time, every 10 days 0.5 h:  Yes 

Yes 

Yes 

Yes 

or Li Storage, LiFePO4 Standstill Trickle Charge (Seasonal):  

  Yes 

Yes 

Yes 

Yes 

Input for Battery Temperature Sensor: 

  Yes 

Yes 

Yes 

Yes 

Power Pack Operation (e. g. Supply During Battery Replacement):    Yes 

Yes 

Yes 

Yes 

 

2. Auxiliary Port Vehicle's Starter Battery 

II 

(Signalling Port Mains)

:

 

Nominal Battery Voltage (Lead): 

12 V  

12 V 

12 V 

12 V  

Charging Current or Rating as Signalling Port: 

0 A-2 A 

0 A-2 A 

0 A-3 A  

0 A-3 A 

Safety Protect. ag. Reverse Batt./Short-circuit/Back Discharge: 

  Yes 

Yes 

Yes 

Yes 

 
 

Connection for Remote Control Automatic Charger: 

  Yes 

Yes 

Yes 

Yes 

Fitting Position of Unit: 

any 

any 

any 

any 

Temperature Range: 

-20/+45 °C 

-20/+45 °C 

-20/+45 °C 

-20/+45 °C 

Speed-controlled, temperature-controlled Fan:  

  Yes 

Yes 

Yes 

Yes 

Gradual Reduction of Charging Capacity at Overtemperature:  

  Yes 

Yes 

Yes 

Yes 

Safety Disconnection in Case of Overheating:  

  Yes 

Yes 

Yes 

Yes 

Noise-reduction of Fan, Night Operation (Silent Run): 

  Yes 

Yes 

Yes 

Yes 

Protection Class/System of Protection: 

I / IP21 

I / IP21 

I / IP21 

I / IP21 

Dimensions, incl. Mounting Flanges (mm): 

215 x 160 x 72   

215 x 160 x 72   

215 x 160 x 72   

215 x 160 x 72 

Weight: 

 

1250 g 

1280 g 

1300 g 

1350 g 

Ambient Conditions, Humidity of Air: 

                                                                   max. 95 % RH, no condensation 

Safety Regulations: 

 

                                                  EN 60335-2-29 

 

 

Содержание Pb 1215 SMT 2B

Страница 1: ...oads such as alarm systems WLAN etc as well as the vehicle s starter battery see page 5 2 Charging Port II Separate auxiliary charging port 12 V 2 A 3 A for support charging and trickle charging of th...

Страница 2: ...the charger will reduce its charging capacity Solid and vibration reducing installation by means of the rubber feet Never remove these rubber feet Battery Connection and Battery Settings for Start up...

Страница 3: ...15 Pb 1220 Pb 1225 Pb 1230 2 5 mm 2 2x 0 6 1 7 m 2x 0 5 1 3 m 4 mm 2 2x 1 0 2 7 m 2x 0 8 2 0 m 2x 0 6 1 6 m 2x 0 5 1 3 m 6 mm 2 2x 1 5 4 0 m 2x 1 1 3 0 m 2x 0 9 2 4 m 2x 0 8 2 0 m 10 mm 2 2x 2 5 6 7 m...

Страница 4: ...e weak battery Sensitive consumers are protected by a voltage limitation in case of very low outside temperatures In case of summery temperatures the charging voltage is reduced to minimize the load g...

Страница 5: ...the internal monitoring functions of the equipment continue working The lighting intensity of the LED Current will be reduced or increased depending on the supplied current intensity It will turn off...

Страница 6: ...harging program IU1oU2oU3 for acid lead acid batteries acc to DIN 57 510 VDE 0510 for charging and trickle charging of supply board batteries Ensures short charging times high charging factor and acid...

Страница 7: ...battery without BMS Battery Management System and without equalization charging of the cells balancing as well as safety circuit is not admissible The battery temperature sensor must be installed at t...

Страница 8: ...d turns off shortly approx every 1 5 sec only with charging program LiFePO4 Li battery protection battery temperature below 0 C the charging current might be reduced for protection of the Li battery i...

Страница 9: ...ull charge point of the battery for automatic switching to U2 In case of slightly discharged batteries the duration of phase U1 will be kept short for relief of the battery and low maintenance expendi...

Страница 10: ...ith a fault current breaker FI with a nominal residual current of 30 mA 3 Connection in consideration of the indicated cable cross sections at the charging ports 4 Fuses of the indicated capacity are...

Страница 11: ...5 0 A Reverse Current from Battery Power Failure 0 5 mA 0 5 mA 0 5 mA 0 5 mA Reset Voltage 30 sec depending on Battery Type 12 75 V 13 25 V 12 75 V 13 25 V 12 75 V 13 25 V 12 75 V 13 25 V Limit of Cha...

Страница 12: ...s Declaration of Conformity In accordance with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022...

Отзывы: