Technical Data: 

Pb 1210 

Pb 1215 

Pb 1220 

Pb 1225 

Pb 1230

 

 

SMT 2B 

SMT 2B 

SMT 2B 

SMT 2B 

SMT 2B

 

 

Nominal Operating Voltage (AC): 

 

                 230 V / 45 – 65 Hz   

 

 

Operating Voltage Range (AC): 

     190 V – 265 V  (Full Charging Capacity), Short-time (5 s) 300 V 

 

 

 

Power Consumption (AC) max.: 

160 W 

240 W 

320 W 

400 W  

520 W

 

Power Consumption (AC) min. (Charging Current 0 A): 

 3.5 W 

 3.5 W 

 3.5 W 

 3.5 W 

 4.0 W

 

Current Consumption (AC) max.: 

 0.7 A 

 1.1 A 

 1.4 A 

 1.8 A  

 2.3 A

 

Sinusoidal Power Factor Correction (PFC, CosPhi = 1): 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

 

Main output Battery I: 

Nominal Battery voltage: 

12 V 

12 V 

12 V 

12 V  

12 V

 

Battery Capacity (recommended): 

 

40Ah-72Ah 

60Ah-110Ah 

80Ah-145Ah 

100Ah-180Ah  120Ah-230Ah

 

Batt. Capacity (acc. to case of application): 

25Ah-115Ah  38Ah-170Ah  50Ah-230Ah    60Ah-290Ah  75Ah-350Ah

 

Charg.Curr. Main Charg., 

I

-Phase, 8 V to U1, 0-15.5 h:  

10 A 

15 A 

20 A 

25 A 

30 A

 

Charg./Floating/Load Curr., contr., U1-,U2(3)Phase:  

0 A – 10 A 

0 A – 15 A 

0 A – 20 A 

0 A – 25 A 

0 A – 30 A

 

Adjust. Charact. Lines of Charg. Gel/AGM/Lead-acid:  

  3 

  3 

  3   

  3 

  3

 

 

Min. Battery Voltage for Charging Start: 

0 V 

0 V 

0 V 

0 V 

0 V

 

Preliminary Charging Current,  
Totally Discharged Battery 0 V-8 V (16 V) 

5.0 A 

7.50 A  

10.0 A  

12.5 A  

15.0 A

 

Reverse Current from Battery (Power off): 

< 0.3  mA 

< 0.3  mA 

< 0.3  mA 

< 0.3  mA 

< 0.3  mA

 

Reset Voltage (30 sec): 

12.75 V 

12.75 V  

12.75 V 

12.75 V 

12.75 V

 

Limit of Charging Voltage (Consumer Protection): 

15 V 

15 V 

15 V 

15 V 

15 V

 

External Overvoltage Disconnection (20 sec.):  

15.5 V 

15.5 V 

15.5 V 

15.5 V 

15.5 V

 

Ripple Factor Voltage: 

< 50mV rms 

< 50 mV rms  < 50 mV rms  < 50 mV rms  < 50 mV rms

 

 

Input Battery I -Temperature Sensor: 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

Charging Timer: 

3-fold 

3-fold 

3-fold 

3-fold 

3-fold

 

Safety Protection against wrong Polarization/Short-Circuit/ 
Back Discharge: 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

Safety Timer per Charging Phase I- /U1-/ (U2-): 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

Battery Regeneration  
in case of extended Down-Time 2 x week: 1 h: 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes 

Power Pack Function (e g battery replacement) 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

 

Auxiliary output Vehicle Starter Battery II: 

Nominal Battery voltage: 

12 V 

12 V 

12 V 

12 V  

12 V

 

Charging Current: 

0 A – 2 A 

0 A – 2 A 

0 A – 2 A  

0 A – 2 A 

0 A – 2 A

 

Safety Protection against wrong Polarization/ 
Short-Circuit/Back Discharge 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

 

Connection for Remote Control Automatic Charger:

 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

 

Mounting Position of Unit: 

   any  

  any 

  any 

  any  

  any 

Temperature Range: 

-20/+45 °C 

-20/+45 °C 

-20/+45 °C 

-20/+45 °C 

-20/+45 °C

 

Built-in Fan with Current and Temperature Control:  

  Yes 

  Yes 

  Yes   

  Yes 

  Yes

 

Gradual Reduction of Charging Capacity in case  
of Overtemperature: 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes 

Safety Disconnection in case of Overheating: 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes 

Noise-reduction of Fan, Night Operation (Silent Run): 

  Yes 

  Yes 

  Yes   

  Yes 

  Yes 

 

Protection Class/System of Protection: 

I / IP21 

I / IP21 

I / IP21 

I / IP21  

I / IP21

 

Dimensions (mm): 

210x138x72   210x138x72   210x138x72   210x138x72 

210x138x72

 

Weight: 

1,250 g 

1,280 g  

1,300 g 

1,350 g 

1,450 g

 

Ambient Conditions, Humidity of Air: 

                            max. 95 % RH, No Condensation

 

Safety Regulations: 

 

                  EN 60335-2-29

 

 

 

Содержание Pb 1210 SMT 2B

Страница 1: ...charging current 12 V 24 V 2 A for support charging and conservation of charge of the vehicle s starter battery with overcharge protection Further Characteristics of the Unit The charging voltage is f...

Страница 2: ...condition 6 Installation in a well ventilated room protected from rain humidity dust aggressive battery gas as well as in an environment being free from condensation water Never use the unit at locati...

Страница 3: ...nsor Temperature Sensor Order No 2001 is required The temperature sensor controls battery temperature I and the temperature dependent correction of the charging voltage It is connected to the unit ter...

Страница 4: ...for connection is included in the delivery scope Connection Just insert the plug of the remote control into the tip jack Remote Control of the charger Functioning The remote control is equipped with t...

Страница 5: ...6 mm2 6 mm2 2 x 1 8 3 0 m 6 mm2 10 mm2 10 mm2 10 mm2 10 mm2 reduce wire cross section at the terminal if necessary CAUTION Safety Instructions Mains connection is only allowed to a shock proof socket...

Страница 6: ...2 6 mm2 6 mm2 6 mm2 6 mm2 2 x 1 8 3 0m 6 mm2 10 mm2 10 mm2 10 mm2 10 mm2 reduce wire cross section at the terminal if necessary CAUTION Safety Instructions Mains connection is only allowed to a shock...

Страница 7: ...V 25 C 2 h U3 Full Conservation Storage Charging 13 40 V 26 8 V 25 C Continuous AGM Charging Program for Lead AGM Fleece Batteries Adapted to closed gas tight AGM absorbet glass mat batteries and bat...

Страница 8: ...ing process will be interrupted The connected batteries will not be discharged by the charger Thus the charging process can be interrupted at any time In case of frequent interruptions particularly be...

Страница 9: ...the charging current an unnecessary long U1 phase is avoided which might be caused by consumer load falsifying the charging current The LED Main Charging will stop lighting 4 U2 Phase LED Battery Ful...

Страница 10: ...pensation In case of 24 V operation Multiply all indicated voltage rates by 2 TS Temperature Sensor Charging Program Gel Charging Program AGM Fleece Characteristic Line IU1oU2 Characteristic Line IU1o...

Страница 11: ...rvoltage Disconnection 20 sec 15 5 V 15 5 V 15 5 V 15 5 V 15 5 V Ripple Factor Voltage 50mV rms 50 mV rms 50 mV rms 50 mV rms 50 mV rms Input Battery I Temperature Sensor Yes Yes Yes Yes Yes Charging...