Assembly instructions VOSSOBW501
SG sensor
, Page 3 of 22
Please observe during the assembly of the VOSS OBW 501
SG sensor
The assembly of the VOSS OBW 501
SG sensor
must be conducted by professional mechanics
subject to these assembly instructions.
Incorrectly assembled sensors can result in failure of the system.
Before using the sensor, components must be checked. They have to be clean and must not
show any signs of damage. In case of any damage, the sensor has to be replaced.
Handle sensor with care to avoid damage due to mechanical shock and electrostatic
discharge.
VOSS OBW 501
SG sensor
is measuring the strain of the material. To make sure the sensor can
measure correctly, the surface has to be clean, straight and free from grease or other release
agents (see chapter “C. Assembly instructions 1. Grinding and cleaning of surfaces”).
To protect the sensor, it hast to be covered by a protection cover and by sealing. The cable has
always to be protected by a corrugated tube. Avoid bending the cable around sharp edges
and below the specified minimum bending radius of 35 mm. The sensor will be adhesive
bonded and the cable fixed on the chassis (see chapter “C. Assembly instructions 2. Assembly
of VOSS OBW 501
SG sensor
”). It is recommended to apply a first fixation of supply cable at a
distance of 150 mm behind the protection cover.
The sensor has a 3-wire harness. For connection and setup instructions see chapter
“C. Assembly instructions 3. Setup of VOSS OBW 501
SG sensor
”.
Observe the manufacturer's safety instructions and handling of adhesive and sealing material.
System properties
For detailed system properties and technical data please check latest available version of
“Product information VOSS OBW 501
SG sensor
” (Art. No. 7007734000) on
www.voss-automotive.net/en/downloads
.
!
!
!
!
!
!
!
!