General
Type Designation
D7A TA KC (1½-circuit)
No. of cylinders
6
Displacement
7,15 liters (740 in
3
)
Dry weight
(1)
, engine without generator and frame, approx.
690 kg (1521 lbs)
Valve clearance, setting values (cold engine)
Inlet
0,30 mm (0,0118’’)
Exhaust
0,50 mm (0,0197’’)
1) excl. engine oil and coolant
Exhaust temperatures
(1)
139 kW @ 1500 rpm
148 kW @ 1800 rpm
at 25% of ISO Standard Power
210°C (410°F)
210°C (410°F)
at 50% of ISO Standard Power
305°C (581°F)
280°C (536°F)
at 75% of ISO Standard Power
390°C (734°F)
330°C (626°F)
at 100% of ISO Standard Power
435°C (815°F)
365°C (689°F)
at 110% of ISO Standard Power
455°C (851°F)
380°C (716°F)
1) Approximated values, temperatures varies with ambient temperature and back pressure in the exhaust line.
General
Type Designation
D7A TA KC (2-circuit)
No. of cylinders
6
Displacement
7,15 liters (740 in
3
)
Dry weight
(1)
, engine without generator and frame, approx.
690 kg (1521 lbs)
Valve clearance, setting values (cold engine)
Inlet
0,30 mm (0,0118’’)
Exhaust
0,50 mm (0,0197’’)
1) excl. engine oil and coolant
Exhaust temperatures
(1)
139 kW @ 1500 rpm
148 kW @ 1800 rpm
at 25% of ISO Standard Power
210°C (410°F)
210°C (410°F)
at 50% of ISO Standard Power
305°C (581°F)
280°C (536°F)
at 75% of ISO Standard Power
390°C (734°F)
330°C (626°F)
at 100% of ISO Standard Power
435°C (815°F)
365°C (689°F)
at 110% of ISO Standard Power
455°C (851°F)
380°C (716°F)
1) Approximated values, temperatures varies with ambient temperature and back pressure in the exhaust line.
Technical Data
47713337 03-2021 © AB VOLVO PENTA
101