10
5.
Remove the thermostat housing and lift out the
thermostat.
NOTE! The forward lifting eye is screwed onto the
thermostat housing.
6.
Remove and discard the O-ring (1) in the heat ex-
changer and if necessary, unscrew the holder (2)
for the ignition cables. The holder is fixed with two
guide pins.
7.
Remove the cap and lift out the strainer (1) from
the heat exchanger. Then pull up the rubber ring’s
tongue (2). The tongue is marked “UP”. The cover
(3) is now loose and can be lifted up. (Not on
AQ125.)
8.
Pull the heat exchanger’s fresh water section to
one side. The fresh water section is mounted on a
rubber bushing (1) and the water pipe (2), which
seals against an O-ring.