43
20. Warning messages on the display
REVERSE POLARITY
CONNECTION BREAK
CONNECT ERROR
CHECK MAIN PORT
BALANCE CONNECT
ERROR
DC IN TOO LOW
DC IN TOO HIGH
CELL ERROR
LOW VOLTAGE
CELL ERROR
HIGH VOLTAGE
CELL ERROR
VOLTAGE-INVALID
CELL NUMBER
INCORRECT
INT.TEMP.TOO HI
EXT.TEMP.TOO HI
OVER CHARGE
CAPACITY LIMIT
OVER TIME LIMIT
BATTERY WAS FULL
The polarity of the battery connections is incorrect.
The battery is not connected (e.g. the battery was disconnected during the
charging cycle).
The battery was connected in the reverse polarity.
The balancer terminal on the battery was not connected properly or was con-
nected in the reverse polarity.
The input voltage (on the direct voltage input) for the charger is too low
(<11 V).
The input voltage (on the direct voltage input) for the charger is too high
(>18 V).
The voltage of one of the lithium battery cells is too low.
The voltage of one of the lithium battery cells is too high.
The voltage of one of the lithium battery cells cannot be measured.
The selected number of cells is incorrect.
The internal charger temperature is too high.
The temperature measured by the external temperature sensor (not included,
available separately) is too high.
The preset capacity limit (see section 19) was exceeded.
The preset time limit for the charging cycle (see section 19) was exceeded.
The connected battery is fully charged. If necessary, check the setting for the
number of cells.
Содержание V-Charge Field 60
Страница 1: ...Operating Instructions Multifunctional charger V Charge Field 60 Item No 1597950...