When installing PAGURO generators, it is important that strict attention be paid to the
following information:
CODES AND REGULATIONS
Federal regulations, ABYC guidelines and safety codes must be complied with when installing
generators in a marine environment.
SIPHON-BREAK
For installation where the external shock absorbers close to or will be below the vessel’s
waterline, provisions must be looped a minimum of 50 cm above the vessel’s waterline. Failure to use
a siphon-break when the external shock absorbers are at or below the load waterline will result in raw
water damage to the engine and possible flooding of the boat.
If you have any doubt about the position of the external shock absorbers relative to the vessel’s
waterline under any of the vessel’s various operating conditions or when the vessel is not underway,
install a siphon-break. This precaution is necessary to protect your engine.
Note:
a siphon-break requires periodic inspections and cleaning to ensure proper operation.
Failure to properly maintain a siphon-break can result in catastrophic engine damage.
Consult the siphon-break manufacturer for a proper maintenance schedule.
EXHAUST SYSTEM
The exhaust hose must be certified for marine use. The system must be designed to prevent
water from entering the exhaust under any sea conditions and at any angle of the vessel’s use.