Service Manual #513659
36
Model F231
B.
Apply a heat sink (wet cloth) to the solenoid valve.
C.
With the suction and discharge ports open, braze
the solenoid into the system.
D.
Remove the heat sink from the valve.
E.
Replace insulation around valve.
F. Replace
the
fi
lter drier. Refer to Section 5.8 for
details.
G.
Evacuate and recharge system per instructions
in Section 5.2.
5.8 FILTER DRIER
The
fi
lter drier must be replaced every time the refrigeration
system is opened for service. A new
fi
lter drier improves
operation of the entire refrigeration system by stopping
the circulation of moisture and by removing harmful con-
taminants (Refer to Figure 5-13).
FILTER DRIER REMOVAL
A.
Recover refrigerant charge per instructions in
Section 5.2.
B.
Cut the refrigeration line as close to the
fi
lter drier
as possible and remove drier.
C.
Cap the ends of the drier using the plugs from
the new drier.
NOTE
The drier must be capped to prevent moisture from
the environment
FILTER DRIER REPLACEMENT
A. Position
the
fi
lter drier so the arrow is pointing
toward the direction of refrigerant
fl
ow (pointing
away from the condenser).
B.
Apply a heat sink (wet cloth) to the
fi
lter drier.
C.
With the suction and discharge ports open, braze
the
fi
lter drier into the system.
D.
Evacuate the system per instructions in Section
5.2.
E.
Recharge the system per instructions in Section
5.3.
Figure 5-14 Capillary Tube and Drier Assembly
5.9 CAPILLARY TUBE
The capillary tube meters refrigerant
fl
ow in the mix line
evaporator (Refer to Figure 5-14). The amount of
fl
ow is
dependent on the length and ID of the capillary tube as
well as the refrigerant charge.
CAPILLARY TUBE REMOVAL
NOTE
The capillary tube assembly contains a drier. The
entire assembly must be removed.
A.
Recover refrigerant charge per instructions in
Section 5.2.
B.
Leave a port open to prevent pressure buildup
during capillary tube removal.
C.
Remove foam insulation from the capillary tube
at the evaporator inlet.
C.
Unsweat the capillary tube and remove.
CAPILLARY TUBE REPLACEMENT
A.
Position the capillary tube in the refrigeration
system.
B.
Apply a heat sink (wet cloth) to the capillary tube
and drier assembly.
C.
With the suction and discharge ports open, braze
the capillary tube into the system.
D..
Replace foam insulation to the capillary tube at
the evaporator inlet.
E.
Evacuate the system per instructions in Section
5.2.
F.
Recharge the system per instructions in Section
5.3.
Figure 5-13 Filter Drier
Содержание Stoelting F231
Страница 1: ...Model F231 SERVICE MANUAL Manual No 513659 Rev 2...