Service Manual #513659
16
Model F231
B. Performance (2 of 2)
The Performance screens display the current status of
the machine. This screen shows the current ambient
temperature, storage temperature and number of cycles
since the Push to Freeze button was pressed or the spigot
was pulled. Press the left arrow to go to the
fi
rst screen.
4.5 SETTINGS SCREENS
A. Modify Operating Settings
This menu provides access to view and change the differ-
ent operating settings on the machine. The Manager and
Technician levels have access to these screens.
B. Basic Settings
This menu contains settings for the control style, CutIn
and CutOut, cycles in serve mode and auger cycle times.
This screen is available to the Technician level.
D. Fine Consistency Adjustment
Product consistency can be adjusted by the Associate
level by using the Fine Consistency Adjustment screen.
Increasing the Fine Consistency number increases the
product consistency (
fi
rmer product).
The Consistency Limits show the Fine Consistency ad-
justment added to the Consistency number.
4.4 PERFORMANCE SCREENS
A. Performance (1 of 2)
The Performance screens display the current status of
the machine. These screens are available to the Manager
and Technician levels. Press the right arrow to go to the
second screen.
Cylinder
The performance information displayed is for the selected
cylinder. To change cylinders press the SEL button.
Consistency*
This is the current consistency number of the selected
cylinder. The consistency number represents how thick
or thin the product in the freezing cylinder is. A higher
number means the product is thicker. Go to the Modify
Operating Settings menu to change the operating setting.
Cylinder Temperature
This is the current suction line temperature of the selected
cylinder.
Motor Amps*
This is the current motor amps of the selected cylinder.
Input Voltage*
This is the current voltage of the selected cylinder.
* Only shown when the drive motor is running
Performance (1 of 2)
Cylinder Right
Consistency 000.00
Cylinder Temp -000.0°F
Motor Amps 00.000A
Input Voltage 000.0V
Performance (2 of 2)
Cylinder Right
Ambient Temp -000.0°F
Storage Temp -000.0°F
Number of Cycles 000
Error Status No Error
Modify Operating Settings
_ Basic Settings
_ Advanced Settings
_ Storage Settings
_ User Preferences
_ Time and Date
Fine Consistency Adjustment
Cylinder Right
Changing the fine consistency
change the firmness of the
product.
Consistency CutIn Limit 00
Consistency CutOut Limit 00
_ Fine Consistency 000
Basic Settings
Cylinder Right
_ Enable Control Consist-Consist
_ CutOut Consist Offset 000
_ CutIn Consist Offset 000
_ CutIn Temp 00.0°F
_ CutOut Temp 00.0°F
_ Cycles In Serve Mode 000
Содержание Stoelting F231
Страница 1: ...Model F231 SERVICE MANUAL Manual No 513659 Rev 2...
Страница 2: ......
Страница 16: ...Service Manual 513659 8 Model F231...
Страница 34: ...Service Manual 513659 26 Model F231...
Страница 50: ...Service Manual 513659 42 Model F231...
Страница 61: ...Service Manual 513659 53 Model F231 8 8 WIRING DIAGRAMS...
Страница 62: ...Service Manual 513659 54 Model F231...