Service Manual #513659
21
Model F231
I. Clear Log Data
The Clear Log Data screen will clear all the errors and
statistics in memory.
J. Restore Factory Defaults / Restore Motor Table
Defaults
The Restore Factory Defaults and Restore Motor Table
defaults screens allow you to restore the control to the
factory con
fi
gurations.
K. Restore Unit Confi guration
The Restore Unit Con
fi
guration screen allows you to
change the motor type default. See section 4.8 for details.
4.7 ERRORS & STATISTICS SCREENS
The Errors & Statistics menu gives the Technician access
to machine statistics and error history.
A. Machine Statistics (1 of 10)
The Machine Statistics screen 1 of 10 shows the time in
serve mode and time in sleep mode. The screen shows
a running total, the total for the previous day and the total
for the previous week for both statistics.
Restore Factory Settings
This will reset all machine
settings to the original
factory configurations. Are
you sure you want to do that
_ No
_ Yes
Errors and Statistics
_ Machine Statistics
_ Error History
Machine Statistics (1 of 10)
Cylinder Right
Time in Serve Mode 0000 hr
Last 24hrs 0000 min
Last 7days 0000 hr
Time in Off Mode 0000 hr
Last 24hrs 0000 min
Last 7days 0000 hr
Restore Motor Table Defaults
This will reset all motor
tables to the original
factory configurations. Are
you sure you want to do that
_No
_Yes
Reset Unit Configuration
This will reset the unit type
and motor types.
Are you sure you want to do that
_ No
_ Yes
Clear Log Data
This will clear the error log
and the statistics.
Are you sure
you want to do that
_ No
_ Yes
Содержание Stoelting F231
Страница 1: ...Model F231 SERVICE MANUAL Manual No 513659 Rev 2...
Страница 2: ......
Страница 16: ...Service Manual 513659 8 Model F231...
Страница 34: ...Service Manual 513659 26 Model F231...
Страница 50: ...Service Manual 513659 42 Model F231...
Страница 61: ...Service Manual 513659 53 Model F231 8 8 WIRING DIAGRAMS...