Service Manual #513659
3
Model F231
Menu
Display
F231
Basic
Enable Control
Consistency/Consistency
CutOut Consist Offset
7
CutIn Consist Offset
20
CutIn Temp
19.5 °F
CutOut Temperature
19 °F
Cycles In Serve Mode
20
Advanced
Standby On Time
10 sec
Standby Off Time
360 sec
Standby Time
120 min
Stir On
15 sec
Stir Off
600 sec
Sleep 2 CutIn
33 °F
Sleep 2 CutOut
30.5 °F
Default Off Time
300 sec
Storage
Storage Refrigeration
Active
Storage CutIn
37.5 °F
Storage CutOut
32 °F
Storage Offset
4 °F
Storage Off Time
13 min
Storage On Time
130 sec
Storage Max On
3 min
Storage Recovery
4 min
Storage Too Warm
50 °F
Storage Too Warm
2 hr
F231
Refrigerant
R-404A
Charge
(W/C) 32 oz
(A/C) 42 oz
Suction Pressure
(at 72°F)
One Cylinder 18-22 psig
Both Cylinders 22-27 psig
Hopper Only 14 psig
Discharge Pressure
225-235 psig
Hot Gas Bypass
Pressure
14 psig (only hopper running)
EPR Valve
68-70 psig
Содержание Stoelting F231
Страница 1: ...Model F231 SERVICE MANUAL Manual No 513659 Rev 2...
Страница 2: ......
Страница 16: ...Service Manual 513659 8 Model F231...
Страница 34: ...Service Manual 513659 26 Model F231...
Страница 50: ...Service Manual 513659 42 Model F231...
Страница 61: ...Service Manual 513659 53 Model F231 8 8 WIRING DIAGRAMS...
Страница 62: ...Service Manual 513659 54 Model F231...