H. Machine Statistics (8 of 10)

The Machine Statistics screen 8 of 10 shows the total run 
time for the pump and counts the total cycles. There is 
an option to reset the timer and the screen shows when 
the last reset was done. The reset should be used if the 
pump is changed.

I. Machine Statistics (9 of 10)

The Machine Statistics screen 9 of 10 shows the amount 
of time the pump hose has been in use and when the 
last reposition was completed. There is also an option to 
reset the hose timer.

J. Machine Statistics (10 of 10)

The Machine Statistics screen 10 of 10 shows when the 
machine was last powered on. The screen also gives an 
average power consumption per day.

Error History 25 of 25
Type                Cylinder Sensor
Date           00/00/00 00:00:00 AM
Cylinder                      Right

_ Status At Time of Error
_ Help

Status at Time of Error
Operating Mode                  Off
Mix Levels               Full Level
Consistency                  000.00
Input Voltage                000.0V
Motor Amps                  00.000A
Ambient Temp               -000.0°F
Cylinder Temp              -000.0°F

K. Error History

The Error History screen shows the last error that occurred. 
The screen shows the type of error, the time and date and 
the cylinder that had the error. Up to 25 errors are stored. 
Press the up or down arrow to scroll through the errors. 
Select the Status at Time of Error option to view data for 
the time the error occurred. The Help option explains the 
error and provides quick troubleshooting tips.

L. Status at Time of Error

The Status at Time of Error screen gives data for the time 
the error occurred.

4.8 UPDATING FIRMWARE

Before starting, make sure there is liquid mix or water in 
the freezing cylinder. The calibration steps should not be 
completed with frozen product in the freezing cylinders.
Firmware is contained in a .rom 

fi

 le which can be down-

loaded from the extranet website or sent via email. Down-
load the .rom 

fi

 le onto the top level of a USB drive (don't 

put the 

fi

 le in a folder and don’t change the name of the 

fi

 le) and follow the instructions below.

A. 

Unplug the machine from electrical power.

NOTE

On a dual power supply machine, unplug both sides.

Machine Statistics (8 of 10)
Cylinder                     Right
Pump Run Time               0000 hr
Pump Cycles                    0000

Last Pump Reset            00/00/00
                        00:00:00 AM
_ Reset Pump Time

Machine Statistics (9 of 10)
Cylinder                     Right

Current Hose Usage          0000 hr
Hose Service Limit           100 hr
Last Hose Reposition       00/00/00
                        00:00:00 AM
_ Reset Hose Service Time

Machine Statistics (10 of 10)

Last Unit Power Up         00/00/00
                           00:00:00

Avg Power KWH/Day           0 Watts

Содержание Stoelting F231

Страница 1: ...Model F231 SERVICE MANUAL Manual No 513659 Rev 2...

Страница 2: ......

Страница 3: ...built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If problems develop or q...

Страница 4: ...ecific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and the...

Страница 5: ...21 Added support for I O update Changed High Torque Error 2 detection to be directly from motor amperage and not from a calculated factor VERSION 20 27 Released on 12 28 10 Added Unit Serial Number to...

Страница 6: ...ge VERSION 17 19 CONTINUED Storage CutOut changed to 32 F was 31 F Storage Offset changed to 4 F was 2 F Storage Off Time changed to 13 min was 2 min Storage On Time changed to 130 sec was 200 sec Sto...

Страница 7: ...mbled Parts 11 3 5 Sanitizing Machine Parts 11 3 6 Cleaning the Machine 11 3 7 Assembling the Machine 12 3 8 Sanitizing 12 3 9 Freeze Down and Operation 13 3 10 Fine Consistency Adjustment 13 3 11 Mix...

Страница 8: ...4 5 7 Solenoid 34 5 8 Filter Drier 36 5 9 Capillary Tube 36 6 Electrical and Mechanical Control Systems 6 1 IntelliTec2 Control 37 6 2 Contactors 37 6 3 Drive Motor 38 6 4 Capacitors 39 6 5 Gearbox 39...

Страница 9: ...provides a uniform product The F231 is designed to operate with almost any type of commercial soft serve or non dairy mixes available including ice milk ice cream yogurt and frozen dietary desserts Th...

Страница 10: ...3 Phase 208 240 VAC 60Hz running amps 12A 10A connection type NEMA 6 20P power cord provided NEMA L15 20P power cord provided International Option 1 Phase 220 240 VAC 50Hz Compressor 12 000 Btu hr R 4...

Страница 11: ...33 F Sleep 2 CutOut 30 5 F Default Off Time 300 sec Storage Storage Refrigeration Active Storage CutIn 37 5 F Storage CutOut 32 F Storage Offset 4 F Storage Off Time 13 min Storage On Time 130 sec Sto...

Страница 12: ...ensor failure will keep the control in Serve and Standby modes only 4 A freeze cycle will reset the stir cycle 5 Serve Mode is active for the Temperature Consistency setting and monitors CutIn Tempera...

Страница 13: ...ng All labels must remain legible for the life of the machine Labels should be checked periodi cally to be sure they can be recognized as warning labels If danger warning or caution labels are needed...

Страница 14: ...ttings option and press the SEL button Then move the cursor to the User Preferences and press the SEL button C On the User Preferences screen move the cursor totheContactInformationUSBUpdateandpress t...

Страница 15: ...quired 1 Press the SEL button to enter the Modify Time and Date screen 2 Move the cursor to the setting that needs to be changed and press the SET button 3 Use the arrow buttons to change the setting...

Страница 16: ...Service Manual 513659 8 Model F231...

Страница 17: ...curs 3 2 OPERATING CONTROLS AND INDICATORS Before operating the machine it is required that the op erator know the function of each operating control Refer to Figure 3 1 for the location of the operat...

Страница 18: ...ort machine statistics 3 3 DISASSEMBLY OF MACHINE PARTS Before using the machine for the first time complete machine disassembly cleaning and sanitizing proce dures need to be followed Routine cleanin...

Страница 19: ...nsult your local and state health codes for the procedures required in your location A Prepare Stera Sheen or equivalent cleaner in 2 gallons of 90 to 110 F 32 to 43 C water following manufacturers in...

Страница 20: ...auger into the freezing cylinder and rotate slowly until the auger engages the drive shaft H Applyathinlayerofsanitarylubricanttotheinside and outside of the auger support bushing Install the bushing...

Страница 21: ...ot to dispense product H The machine dispenses product at a reasonable draw rate If the machine is overdrawn the result is a soft product or a product that will not dispense at all If this occurs allo...

Страница 22: ...oper product serving temperature varies from one manufacturer s mix to another Mixes should provide a satisfactory product in the 20 F to 24 F range Diet and low carb mixes typically freeze to proper...

Страница 23: ...d sequence Press the left ar row button from the Current Status screen to access the passcode input screen The specific readings and parameters available depend on the keypad sequence entered The lowe...

Страница 24: ...row to go to the second screen Cylinder The performance information displayed is for the selected cylinder To change cylinders press the SEL button Consistency This is the current consistency number o...

Страница 25: ...d Sleep 2 Mode Stir Off is the amount of time between stir cycles Stir cycles occur in Serve Mode Standby Mode and Sleep 2 Mode D Advanced Settings 2 of 2 TheAdvanced Settings menu contains standby an...

Страница 26: ...will be displayed G User Preferences The User Preferences menu contains language options temperature units service contact information and touch pad lockup The screen is available to the Manager and...

Страница 27: ...d unlock the keypad for self service locations D Export Machine Stats The Export Machine Stats screen allows you to export all the data and statistics stored in the control Connect a USB flash drive t...

Страница 28: ...ed to Open G Motor Calibration The Motor Calibration screen is used when a motor is replaced or the control firmware is updated Move the cursor to the correct option and press the SEL button to calibr...

Страница 29: ...time in sleep mode The screen shows a running total the total for the previous day and the total for the previous week for both statistics Restore Factory Settings This will reset all machine setting...

Страница 30: ...revi ous week C Machine Statistics 3 of 10 The Machine Statistics screen 3 of 10 provides the time and date that the freezing cylinder was last cleaned This value is recorded when the Clean button is...

Страница 31: ...hat had the error Up to 25 errors are stored Press the up or down arrow to scroll through the errors Select the Status at Time of Error option to view data for the time the error occurred The Help opt...

Страница 32: ...l has completed this step it will automatically restart O Enter the technician password to the control by pressingtherightarrow SET thentheSELbutton P Navigate to the Utilities menu and select the Nex...

Страница 33: ...irty place a wet towel over the condenser C Using compressed air or CO2 tank blow out the dirt from the back of the condenser Most of the dirt will cling to the wet towel D Analternativemethodistoclea...

Страница 34: ...Service Manual 513659 26 Model F231...

Страница 35: ...or qualified service personnel only Anybody work ing with refrigerants must be certified as a Techni cian TYPE I as required by 40 CFR 82 Subpart F and hold all State and or local refrigerant handling...

Страница 36: ...tion 4 for details 8 Evacuate the system until the gauge reads 300 microns of mercury 300 Hg for 5 continuous minutes 10 If the system will not maintain a standing vacuum test with the vacuum pump off...

Страница 37: ...movetheprotectivecoverfromthecompressor terminals and disconnect the wires D Recover refrigerant charge per the instructions in Section 5 2 E Leave the suction and discharge ports open to prevent pres...

Страница 38: ...constant superheat at the exit of the evaporator The self regulating TXV is preset by the manufacturer and adjustment is not recommended Figure 5 3 TXV TESTING ADJUSTMENT NOTE The bulb has an indent...

Страница 39: ...ends the gauge should read the following OT2 Models 22 24 psig YG2 Models 23 25 psig YG2ME Models 18 20 psig This reading is based on a full load in the freezing cylinder D If the pressure reading is...

Страница 40: ...hes 445 psig 9 HIGH PRESSURE CUTOUT REMOVAL A Remove the left side panel B Recover refrigerant charge per instructions in Section 5 2 C Leave the suction and discharge ports open to prevent pressure b...

Страница 41: ...E Evacuate and recharge system per instructions in Section 5 2 F EVAPORATOR PRESSURE REGULATOR EPR There is one EPR in the refrigeration system Refer to Figure 5 9 It is located on the suction line o...

Страница 42: ...E Remove the clamps from the water lines at the valve F Remove the two screws holding the water valve to the frame and remove the valve WATER VALVE REPLACEMENT To replace the water valve perform the f...

Страница 43: ...t flow is monitored through the system If the valve seat does not leak the suction pres sure during the test will be low A Attach a gauge to the Schrader valve on the suction line B Turn the machine o...

Страница 44: ...sink wet cloth to the filter drier C With the suction and discharge ports open braze the filter drier into the system D Evacuate the system per instructions in Section 5 2 E Recharge the system per in...

Страница 45: ...rig ger the contactors Separate signals are used to control eachdrivemotorcontactorandthecompressorcontactor The signals to the contactors are staggered so the drive motor will always start three seco...

Страница 46: ...ermal overload A DRIVE MOTOR TEST 1 Turn the machine off by pressing the Main Power Off On button and disconnect the machine from the electrical supply 2 Remove the back panel and a side panel 3 Loose...

Страница 47: ...1 Disconnectmachinefromelectricalsupplybefore removing any panels for servicing 2 Remove the back panel and the side panel 3 Removethefournutsholdingthesupportbracket and remove the bracket 4 Remove...

Страница 48: ...after the product is at consistency in Serve Mode or when the machine is empty 1 Open the spigot slowly and listen for a click when the spigot switch closes 2 The clicking sound should be within the...

Страница 49: ...used to sense the temperature of the suction line As the suction line temperature increases the internal resistance of the thermistor will decrease Refer to Figure 6 7 for the relationship between se...

Страница 50: ...Service Manual 513659 42 Model F231...

Страница 51: ...here is a possibility that the mix is broken down clean and sanitize the machine and replace the mix with fresh product Ice crystals in the hopper can clog the mix inlet regulator and prevent mix from...

Страница 52: ...n the internal timer to expire then press the On Off button for the cylinder to turn it back on In air cooled condenser models check the air filter to make sure it is clean Replace or clean the filter...

Страница 53: ...ndforcontinuity Ifcontinuityisfound replace the sensor To check the resistance of the sensor place a thermocouple on the suction line at the exitofthefreezingcylinder Comparetemperature andsensorresis...

Страница 54: ...ean reassemble sanitize and freeze down 6 Refrigeration problem 6 Check system Product does not dispense 1 No mix in hopper 1 Add mix to the hopper 2 Drive motor overload tripped 2 Wait for automatic...

Страница 55: ...1 324393 Decal Stoelting Swirl Logo 1 324509 Decal Cleaning Instructions 1 324566 Decal Wired According To 1 324584 Decal Adequate Ventilation 3 3 324594 Decal Attention Heat Sensitive 4 324686 Decal...

Страница 56: ...13659 48 Model F231 8 3 AUGER SHAFT AND FACEPLATE PARTS 3170644 149003 4157968 381804 694255 624678 5 666786 625133 2177428 2187812 2187811 624664 5 624614 5 624598 5 417006 744273 744262 2149241 2149...

Страница 57: ...86 Seal Rear Auger Black 2 694255 Spring Auger Flight 8 744262 Tray Drain Black Plastic 1 744273 Tray Drip 1 2149241 Mix Inlet Assembly 5 16 Hole Extended Length 2C 2149243 01 Mix Inlet Assembly 3 16...

Страница 58: ...5 763423 282032 SV 282033 SV 282050 SV 342020 458003 718794 762454 762490 762978 763017 763422 763482 2202316 522858 SV 522859 523345 231107 342004 295112 521513 521514 521516 522291 284084 162077 618...

Страница 59: ...wer 3 PH 1 458003 Sight Glass 1 493115 Light Red LED Mix Low 2 521513 Board Program IntelliTec2 1 521514 Board Relay IntelliTec2 1 521516 Board Program Relay IntelliTec2 1 522291 Motor Fan Air Cooled...

Страница 60: ...witch Limit Spigot Cam 3 2158082 Glide Spigot Socket 3 2187805 Handle Spigot Handle Only 3 Part Description Quantity 332563 Board Display Module Display Only 1 482004 Knob Spigot Adjustment 3 719128 S...

Страница 61: ...Service Manual 513659 53 Model F231 8 8 WIRING DIAGRAMS...

Страница 62: ...Service Manual 513659 54 Model F231...

Страница 63: ...ons remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Start Up and Training Checklist for the affected equipment b gives Stoelting prompt written...

Отзывы: