H. Machine Statistics (8 of 10)
The Machine Statistics screen 8 of 10 shows the total run
time for the pump and counts the total cycles. There is
an option to reset the timer and the screen shows when
the last reset was done. The reset should be used if the
pump is changed.
I. Machine Statistics (9 of 10)
The Machine Statistics screen 9 of 10 shows the amount
of time the pump hose has been in use and when the
last reposition was completed. There is also an option to
reset the hose timer.
J. Machine Statistics (10 of 10)
The Machine Statistics screen 10 of 10 shows when the
machine was last powered on. The screen also gives an
average power consumption per day.
Error History 25 of 25
Type Cylinder Sensor
Date 00/00/00 00:00:00 AM
Cylinder Right
_ Status At Time of Error
_ Help
Status at Time of Error
Operating Mode Off
Mix Levels Full Level
Consistency 000.00
Input Voltage 000.0V
Motor Amps 00.000A
Ambient Temp -000.0°F
Cylinder Temp -000.0°F
K. Error History
The Error History screen shows the last error that occurred.
The screen shows the type of error, the time and date and
the cylinder that had the error. Up to 25 errors are stored.
Press the up or down arrow to scroll through the errors.
Select the Status at Time of Error option to view data for
the time the error occurred. The Help option explains the
error and provides quick troubleshooting tips.
L. Status at Time of Error
The Status at Time of Error screen gives data for the time
the error occurred.
4.8 UPDATING FIRMWARE
Before starting, make sure there is liquid mix or water in
the freezing cylinder. The calibration steps should not be
completed with frozen product in the freezing cylinders.
Firmware is contained in a .rom
fi
le which can be down-
loaded from the extranet website or sent via email. Down-
load the .rom
fi
le onto the top level of a USB drive (don't
put the
fi
le in a folder and don’t change the name of the
fi
le) and follow the instructions below.
A.
Unplug the machine from electrical power.
NOTE
On a dual power supply machine, unplug both sides.
Machine Statistics (8 of 10)
Cylinder Right
Pump Run Time 0000 hr
Pump Cycles 0000
Last Pump Reset 00/00/00
00:00:00 AM
_ Reset Pump Time
Machine Statistics (9 of 10)
Cylinder Right
Current Hose Usage 0000 hr
Hose Service Limit 100 hr
Last Hose Reposition 00/00/00
00:00:00 AM
_ Reset Hose Service Time
Machine Statistics (10 of 10)
Last Unit Power Up 00/00/00
00:00:00
Avg Power KWH/Day 0 Watts
Содержание Stoelting F231
Страница 1: ...Model F231 SERVICE MANUAL Manual No 513659 Rev 2...
Страница 2: ......
Страница 16: ...Service Manual 513659 8 Model F231...
Страница 34: ...Service Manual 513659 26 Model F231...
Страница 50: ...Service Manual 513659 42 Model F231...
Страница 61: ...Service Manual 513659 53 Model F231 8 8 WIRING DIAGRAMS...
Страница 62: ...Service Manual 513659 54 Model F231...