Automatic Expansion Valve for Lemon Ice:
Original Factory Setting 40 PSIG
Typical pressure settings for Lemon Ice: 40 PSIG
Your final valve setting for Custard
________
Your Final valve setting for Lemon Ice
________
Note: each machine will differ slightly in preferred setting.
Condensing Unit Settings: Air Cooled Units
(Location on each condensing unit)
Danfoss Head Pressure Control:
Adjustable at 255 PSIG
High Pressure Safety Cut-Out:
Non Adjustable at Approx. 350 PSIG
Low Pressure Safety Cut-Out:
Cut-In 20 PSIG
Cut-Out 5 PSIG
Fan Cycling Controls:
Non Adjustable at 180 PSIG
Crankcase
Pressure
Regulator
25
PSIG