User Manual VAS 5054A V1.06 All rights reserved.
Page 33
VAS 5054A User Manual
3. After installation is complete, the VAS 5054A must be detected by the Bluetooth software.
The software offers a function for listing all the Bluetooth devices in range. Make sure your
VAS 5054A is connected to the power supply and is within range. The VAS 5054A then has
to appear in this list. Select the VAS 5054A the list and have the software discover the
services provided by the VAS 5054A (a Bluetooth serial port is the only service that is
allowed to be discovered). A prompt appears asking you to enter the PIN of the VAS 5054A.
Type in the serial number of the VAS 5054A, which is indicated on the ID plate.
4. Using the Bluetooth software, connect to the VAS 5054A. The connection may have already
been established during service discovery. A COM port for outgoing connections, which
was created by the Bluetooth software, is displayed on your PC. You will need the identifier
of this COM port when installing the application software.
5. Install the application software as described in sections 3.5 to 3.7.
6.3 Error Messages during Self-Diagnosis
FAQ 8 I get the error message: No EDIC is installed. What does that mean?
No VAS 5054A is currently installed. Connect to the VAS 5054A with your Bluetooth software.
Note down the COM port that your Bluetooth software has assigned to the VAS 5054A.
Install the VAS 5054A you want to use with your diagnostic application. You will find a detailed
description of how this is done in section 3.7.
FAQ 9 I get the error message
The EDIC-API delivers a system error
. In the details, the
error IFH-0002 (NO RESPONSE FROM INTERFACE) is indicated. What does that
mean?
The connection to the VAS 5054A has been interrupted. Possible reason:
The VAS 5054A was (temporarily) disconnected from the power supply during a diagnostic
session.
Plug the VAS 5054A back in. Click
Aborting
and restart your diagnostic session.
FAQ 10 I get the error message
The EDIC-API delivers a system error
. In the details, the
error IFH-0003 (DATATRANSMISSION TO INTERFACE DISTURBED) is indicated.
What does that mean?
The connection to the VAS 5054A has been interrupted. Possible reason:
The VAS 5054A was (temporarily) disconnected from the power supply during a diagnostic
session.
Plug the VAS 5054A back in. Click
Aborting