Connect the pressure gauge to the wheel cylinder (rear). Unscrew the bleeder valve for this. Operate the brake pedal with
enough pressure to achieve the inlet pressure (see signboard of braking force regulator), then adjust the outlet pressure.
After the check, bleed the brake system. Tighten the bleeder valve by MA=4,9+1Nm.
With the specified axle loads, every pressure within the tolerance limits is permitted (e. g. 600 - 630 kg = 4-7 bar).