16
Fig.13
EXTENDING THE FLUE
Connect the bend – supplied with the terminal kit – to the top
of the boiler using clamp (supplied) see ig. 11. The additional
bends & extensions have push-it connections, care should be
taken to ensure that the correct seal is made when assembling
the lue system. Connect the required number of lue exten
-
sions or bends (up to the maximum equivalent lue length) to
the lue terminal (see ig. 11-14).
The lue system should have
a minimum of 1º; maximum of 3º rise from the boiler to outside,
to ensure any condense luid that forms, is allowed to drain
back to the appliance.
NOTE
When cutting an extension to the required length, you must
ensure that the excess is cut from the plain end of the extension
(see ig. 11-14). Remove any burrs, and check that all seals are
located properly. You must ensure that the entire lue system is
properly supported and connected. Seal the lue assembly to
the wall using cement or a suitable alternative that will provide
satisfactory weatherprooing. The interior and exterior trim can
now be itted.
Fig. 14
A
4.5.1.2 FITTING THE REAR FLUE (ig. 15) (rear lue outlet
only)
Using the template provided, mark and drill a 125mm hole
for the passage of the lue pipe. The hole should be drilled
LEVEL to ensure any condense luid that forms, is allowed
to drain back to the appliance. The ixing holes for the wall-
mounting bracket should now be drilled and plugged, an ap-
propriate type and quantity of ixing should be used to ensure
that the bracket is mounted securely. Once the bracket has
been secured to the wall, attach the rear lue terminal to the
appliance (using the previously retained screws) and ix the
telescopic terminal to the correct length (wall thickness) en-
suring that the terminal will protrude through the wall by the
correct distance. At this point, lift the appliance and carefully
insert the terminal into and through the wall, ensuring that the
holes in the appliance back frame are aligned with the studs
on the wall bracket.
Fig.15
Fig.17
Using the screws and washers provided, secure the appliance
onto the wall bracket and tighten with a suitable spanner.
Seal the lue assembly to the wall using cement or a suitable
alternative that will provide satisfactory weatherprooing. The
exterior wall trim can now be itted.
Fig.16
Fig. 12
Part No.
Description
Length
29450133
Rear lue terminal
825mm