4.5.2 CONCENTRIC VERTICAL FLUE

The appliance can be used with either the Vokèra condensing 

60/100mm concentric lue system or the optional 80/125mm 

concentric lue system.  

NOTE

These instructions relate 

only

 to the Vokèra condensing 

60/100mm concentric lue system. For speciic details on the 

installation of the 80/125mm concentric lue system please refer 

to the instructions supplied.

The vertical lue terminal can be connected directly to the ap

-

pliance lue outlet. Alternatively, an extension or bend can be 

connected to the appliance lue outlet if desired, however if 

additional bends are itted, a reduction must be made to the 

maximum lue length (see table below).

Reduction for bends

  Bend  

Reduction in maximum lue length for each bend

 45º bend 

1.3 metre (60/100) - 1.0 metre (80/125)  

 90º bend 

1.6 metre (60/100) - 1.5 metre (80/125) 

Vertical lue terminal and accessories

  

Part No. 

Description  

Length

 

  29450122  Vertical lue terminal  

1000mm 

  531 

Pitched roof lashing plate 

N/A 

  532 

Flat roof lashing plate 

N/A 

  29450123 

90-degree bend 

N/A 

  29450124 

45-degree bends (pair) 

N/A 

  29450125 

500mm extension 

500mm 

  29450126 

1000mm extension 

1000mm 

  29450127 

2000mm extension 

2000mm 

  29450128 

Telescopic extension 

372/519mm

  529 

Wall bracket pack (5) 

208mm

Using the dimensions given in ig. 18 as a reference, mark and 

cut a 125mm hole in the ceiling and/or roof.

Fig. 18

“X”

12/15/20HE = 202mm
25/30/35HE = 218mm

130mm

Fit the appropriate lashing plate to the roof and insert the ver

-

tical lue terminal through the lashing plate from the outside, 

ensuring that the collar on the lue terminal its over the lashing.

The ixing holes for the wall-mounting bracket should now be 

drilled and plugged, an ‘appropriate type and quantity of ixing 

should be used to ensure that the bracket is mounted securely. 
Once the bracket has been secured to the wall, mount the ap-
pliance onto the bracket.

IMPORTANT

The vertical lue terminal is 1.0 metre in length and cannot be 

cut; therefore it may be necessary to adjust the height of the 
appliance to suit or use a suitable extension.

Connect the vertical lue assembly to the boiler lue spigot us

-

ing the 100mm clip, gasket & screws (supplied), ensuring the 

correct seal is made. The lue support bracket (supplied with 

the vertical lue kit) can now be itted. 

If the vertical lue requires extension/s or additional bend/s, 

connect the required number of lue extensions or bends (up 

to the maximum equivalent lue length) between the boiler and 

vertical lue assembly (see ig. 14).

Ensure that any horizontal sections of the lue system have a 

minimum 1º; maximum 3º fall back to the boiler (1º = 17mm 
per 1000mm).

NOTE

When cutting an extension to the required length, you must 
ensure that the excess is cut from the plain end of the exten-
sion. Remove any burrs, and check that any seals are located 
properly.

You must ensure that the entire lue system is properly sup

-

ported and connected.

4.5.3 TWIN FLUE SYSTEM

The Vokèra twin lue system enables greater lue distances 

to be achieved than that of a concentric lue system. It can be 

used for horizontal or vertical applications, however the twin 

lue  system  must  be  converted  to  the  dedicated  concentric 

lue kit for termination. It is essential that the installation of the 

twin lue system be carried out in strict accordance with these 

instructions.

GUIDANCE NOTES ON TWIN FLUE INSTALLATION 

• The lue must have a have a minimum 1º; maximum 3º (1º = 

17mm per 1000mm) fall back to the appliance to allow any 

condensate that may form in the lue system to drain via the 

condensate drain. Consideration must also be given to the 
fact that there is the possibility of a small amount of conden-
sate dripping from the terminal.

•  Ensure that the entire lue system is adequately supported, 

use at least one bracket for each extension.

•  As the exhaust outlet pipe can reach very high temperatu

-

res it must be protected to prevent persons touching the hot 
surface.

•  The condensate drain pipe must be connected in accordan

-

ce with building regulations

Reduction for bends

  Bend  

Reduction in maximum lue length for each bend

  45º bend 

1.0 metre 

  90º bend 

1.5 metre 

Twin lue accessories

  

Part No. 

Description 

Length 

  0225805  Horizontal lue terminal 

1.0 metre

  0225810  Vertical lue terminal 

1.0 metre

  359 

Twin adapter kit 

N/A 

  531 

Pitched roof lashing plate 

N/A 

  532 

Flat roof lashing plate 

N/A 

  0225815 

Condensate drain kit 

N/A 

  0225820 

0.25m extension  (pair) 

250mm 

  0225825 

0.5m extension (pair) 

500mm 

  0225830 

1.0m extension (pair) 

1000mm

  0225835 

2.0m extension (pair) 

2000mm

  0225840 

45º bend (pair) 

N/A 

  0225845 

90º bend (pair) 

N/A 

  0225850 

Twin bracket (5) 

N/A 

  0225855 

Single bracket (5) 

N/A 

MOUNTING THE BOILER

The ixing holes for the wall-mounting bracket should now be 

drilled and plugged, an appropriate type and quantity of ixing 

should be used to ensure that the bracket is mounted securely.  
Once the bracket has been secured to the wall, mount the ap-
pliance onto the bracket.

Содержание Vision C

Страница 1: ...ctions THESE INSTRUCTIONS TO BE RETAINED BY USER Vok ra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems...

Страница 2: ...3A 4 Flue system 13 3A 5 Air supply 14 3A 6 Water circulation 14 3A 7 Electrical supply 14 3A 8 Mounting on a combustible surface 14 3A 9 Timber framed buildings 14 3A 10 Inhibitors 14 3A 11 Showers 1...

Страница 3: ...tically Dear Customer Your Vok ra Vision boiler has been designed to meet and exceed the very latest standards in gas central heating technology and if cared for will give years of reliable use and ef...

Страница 4: ...shows the temperature values Pressure gauge shows the current pressure of your heating system the gauge should be set between 1 and 1 5 BAR When the appliance is oper ating the gauge may rise or fall...

Страница 5: ...ADVANCE ON fun ction is active Displayed when the ADVANCE OFF fun ction is active Displays current minutes past the hour Displays current hour of the day 24 hour clock in 30 minute segments lar ge se...

Страница 6: ...y of week setting procedure NOTE the time of day is shown on the display and is also indicated on the 24 segmented display as a lashing segment 1 4 CHANGING THE HEATING PATTERN The built in clock is p...

Страница 7: ...he programmed heating pattern AUTO ON Heating is in an ON period according to the programmed heating pattern MAN OFF Heating is being controlled manually and is switched constantly OFF MAN ON Heating...

Страница 8: ...ow a period of at least two minutes before re setting the appliance 2 6 EXPLANATION OF FEATURES Although the Vok ra Vision has been designed for simplicity of use it utilises the latest in boiler tech...

Страница 9: ...r A01 Ignition failure lame not sensed internal fault Final Reset check appliance operation A02 Limit thermostat fault Final Reset check appliance operation A03 Fan tacho signal fault Final Reset chec...

Страница 10: ...on open vented systems This booklet is an integral part of the appliance It is therefore necessary to ensure that the booklet is handed to the person responsible for the property in which the applianc...

Страница 11: ...nd the boiler will perform a three minute anti cycle timer delay When the request for heat has been satisied the appliance pump and fan may continue to operate to dissipate any residual heat within th...

Страница 12: ...mum system volume 74 litres Pre charge pressure 1 bar 2 5 Dimensions Vision 25C Vision 30C Height mm 715 Width mm 405 Depth mm 248 Dry weight kg 27 28 2 6 Clearances Vision 25C Vision 30C Sides 12mm T...

Страница 13: ...to the roof lashing As determined by the ixed collar of the vertical terminal R To the side of a boundary 300 mm S To the side of an opening or window on a pitched roof 600 mm T Below an opening or w...

Страница 14: ...ansion vessel to accom modate the increased volume of water when the system is heated It can accept up to 8 litres of expansion from within the system generally this is suficient however if the system...

Страница 15: ...itted on a wall of combustible mate rial there is no requirement for a sheet of ireproof material to protect the wall 3 9 TIMBER FRAMED BUILDINGS If the appliance is to be itted in a timber framed bu...

Страница 16: ...An alternative method of illing the system would be from an independent make up vessel or tank mounted in a position at least 1 metre above the highest point in the system and at least 5 metres above...

Страница 17: ...plane see2 9 Areductionmustalsobemadetothemaximumlength see table below when additional bends are used Reduction for additional bends Bend Reduction in maximum lue length for each bend 45 bend 1 3 me...

Страница 18: ...REAR FLUE ig 15 rear lue outlet only Using the template provided mark and drill a 125mm hole for the passage of the lue pipe The hole should be drilled LEVEL to ensure any condense luid that forms is...

Страница 19: ...ired number of lue extensions or bends up to the maximum equivalent lue length between the boiler and vertical lue assembly see ig 14 Ensure that any horizontal sections of the lue system have a minim...

Страница 20: ...e kit for termination The horizontal terminal is supplied with a built in converter box and cannot be shortened A 130mm hole is required for the passage of the concentric terminal through the wall The...

Страница 21: ...ad can be used for connection to the electrical supply Connect the ly lead to a fused plug or fused isolator in the following way brown wire to LIVE supply blue wire to NEUTRAL supply green yellow to...

Страница 22: ...ectrical supply to the appliance is switched on Ensure any external controls are switched to an ON position and are calling for heat Move the selector switch to the ON position the appliance will now...

Страница 23: ...LY AND IS PROPERLY SECURED ENSURE ALL PIPE WORK IS RE CHECKED FOR TIGHT NESS RE FIT APPLIANCE CASING COMPLETE BENCHMARK CHECKLIST FOR UK ONLY Complete details of the boiler controls installation and c...

Страница 24: ...n the reverse order 6 7 LOWER AUTOMATIC AIR RELEASE VALVE ig 28 Carry out component removal procedure as described in 6 4 Remove the expansion pipe locking pin B from the pump as sembly and remove the...

Страница 25: ...dition taking care to Fig 34 6 13 ELECTRODES ig 34 Carry out component removal procedure as described in 6 4 Remove the air chamber front cover Disconnect the electrode leads and ancillary wiring from...

Страница 26: ...removal procedure as described in 6 4 Remove the locking pin Q1 that secures the cover R1 to the hydraulic manifold Using a hooked piece of wire carefully withdraw the by pass cartridge S1 and or DHW...

Страница 27: ...unscrew the inlet connection Unscrew the nut E2 Lift the DHW low switch housing from its seating If necessary remove the locking pin F2 from the DHW low switch taking care not to lose the loat contain...

Страница 28: ...ow 35 C and 55 C respectively the boiler will ire on minimum 25 power until the primary thermistor exceeds 55 C Thereafter the pump will over run for a period of 30 seconds 7 2 3 HEATING MODE With the...

Страница 29: ...emed as immediately dangerous 7 5 CHECKING THE EXPANSION VESSEL Carry out the component removal procedure as described in 6 4 You must ensure that the boiler is completely drained of water Using a sui...

Страница 30: ...mpletion of any task that required the disconnection and re connection of any electrical wiring or component these checks must be repeated 7 8 FAULT FINDING Before attempting any faultinding the elect...

Страница 31: ...ressed in hundreds e g 25 2 500 rpm GAS VALVE CALIBRATION Connect the boiler to the power supply Open the gas tap Set the function selector to OFF RESET monitor off Remove the screws E remove the casi...

Страница 32: ...st the temperature of the heating system indirectly by changing the required room temperature from between 15 C 25 C this will allow the PCB to recalculate the system temperature required the default...

Страница 33: ...controls manufacturer and or Vok ra technical department should you require more speciic information on the suitability of a particular control Further guidance on the recom mended practice for the in...

Страница 34: ...ssure switch S E Spark electrode TSC2 Ignition transformer 3W 3 way motor F O H T Flow over heat thermostat FS Flue sensor FT Flow thermistor NTC RS Return thermistor NTC brown CN3 blue F Hv 1 2 7 1 C...

Страница 35: ...HE APPLIANCE GAS TYPE To convert the appliance to another gas type it is necessary to change the injector and adjust the gas valve CO2 To change the injector see 6 12 1 Toreplacethelangeonthesilencer...

Страница 36: ...7 3 However if the CO2 reading is incorrect the minimum gas pressure must be adjusted as follows locate the minimum adjustment screw ig 44 using a suit able screwdriver remove the protection plug usi...

Страница 37: ......

Страница 38: ...36...

Страница 39: ...38...

Страница 40: ...ies vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 0999 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limited reserve t...

Отзывы: